GAQW3V330 Operation
Efficiency
94
14
Power Dissipation
Power Dissipation (W)
92
12
10
8
6
4
2
0
0
5
10
15
20
Efficiency (%)
90
88
86
84
82
80
0
5
10
15
20
25
30
36V Vin
48V Vin
75V Vin
36V Vin
48V Vin
75V Vin
25
30
Output Current (A)
Output Current (A)
Start Up
Voltage Ripple
CH2
CH1
CH3
1) Vout 1V 4mS/div
2) Iout 10A/div
3) Enable 5V/div
1) Vout 20mV/div 2µS/div
10µF ext cap 20MHz BW
Transient Response
3.37
Line/Load Regulation
Setpoint Accuracy 0.8061%
Line Regulation 0.0595%
Load Regulation 0.0397%
Line & Load Regulation 0.0839%
Output Voltage (V)
3.35
3.33
3.31
3.29
3.27
3.25
3.23
0
5
10
36V Vin
48V Vin
75V Vin
15
20
25
30
1) Vout 500mV/div 200µS/div
2) Iout 10A/div
Output Current (A)
Part No. 02-GAQ-02 Rev. 3.0 – 041405
WWW.GALAXYPWR.COM
Telephone: 508-870-9775
Fax: 508-870-9796
GAQW3V330 – 5
Galaxy Power Inc.
155 Flanders Road
Westborough, MA 01581
e-mail: info@galaxypwr.com