General Specifications  
V
= 48V , T @25 °C, 300 LFM airflow, V  
=3.3V, I  
= Full Load unless otherwise noted.  
OUT  
IN  
DC  
A
OUT  
Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)  
Input Characteristics  
Parameter  
Min  
Typ  
Max  
75  
Units  
Operating Input Voltage  
36  
48  
V
DC  
Input Current (Model Dependent)  
Input Capacitance  
8.0  
A
6.6  
2
µF  
Input Hysteresis, Low Line  
Output Characteristics  
V
DC  
Regulation Over Line, Load & Temperature  
98  
102  
25  
%V  
mV  
mV  
NOM  
RMS  
P–P  
Voltage Ripple  
Voltage Ripple, 20MHz BW  
Current Range  
125  
60  
0
A
Current Limit Inception  
62  
72  
A
A
Short Circuit Current, Peak (see Note below)  
Output Transient Response, 50% to 75% load change, 1A/µsec  
Settling Time to ±1%  
75  
125  
300  
30  
mV  
µS  
mS  
Turn-on Time to 98% Vnom  
Output Overshoot at Turn-on  
Trim Range  
1
%V  
OUT  
OUT  
OUT  
90  
110  
%V  
%V  
Overvoltage Protection, Latching  
130  
200  
Isolation  
Isolation Test Voltage, Input/Output (Basic)  
Isolation Resistance  
2000  
10  
V
DC  
M  
Features  
Overtemperature Protection, Thermal Sensor, Latching*  
117  
°C  
Input, Output Ripple Frequency, Fixed**  
kHz  
Notes: During short circuit, converter will shut down and attempt to restart once per second.  
The average current during this condition will be very low and the device can be safely left in this condition  
continuously. For specific output voltage specifications, see the corresponding detailed data sheet.  
*PCB less than 130°C  
**3V360 = 300kHz  
General Specifications  
Approvals and Standards  
Operating Temperature  
Storage Temperature  
Relative Humidity  
-40°C to +100°C  
–55°C to +125°C  
10% to 95% RH,  
Non-condensing  
2 to 9Hz, 3mm disp.  
9 to 200Hz 1g  
UL V-0  
UL and c-UL Recognized Component,  
TUV, UL60950, CSA 22.2 No. 950,  
IEC/EN60950**  
EMC Characteristics:  
Vibration  
Designed to meet emission and immunity  
requirements per EN55022, CISPR22,  
Class B and CISPR24.  
Material Flammability  
Weight  
55 grams  
** An external fuse shall be used to comply with the requirements.  
MTBF  
Telcordia (Bellcore)  
1,300,000 hours  
Taurus HC Series, Page 2  
Part No. 01–001 Rev. 4.0_082803  
WWW.GALAXYPWR.COM