GM317
3-TERMINAL 1.5A
ADJUSTABLE REGULATOR
Electrical Characteristics (Unless otherwise noted, VI - VO = 5V and IO= 0.5A. TJ = Full
Range, unless otherwise noted)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
0.01
0.02
65
0.04
0.07
3V ≤ VIN – VOUT ≤ 40V, TJ = 25°C
3V ≤ VIN – VOUT ≤ 40V,
Line Regulation (note 2)
∆VOI
%/V
VOUT = 10V, f = 120Hz
Ripple Rejection Ratio
Load regulation (note 3)
dB
VOUT = 10V, f = 120Hz, 10µF
66
80
capacitor between ADJ and GND
VO ≤ 5V
5
25
0.5
70
mV
%
10mA ≤ IOUT ≤ 1.5A,
TJ = 25°C
0.1
20
0.3
VO > 5V
∆VOL
∆VOT
VO ≤ 5V
10mA ≤ IOUT ≤ 1.2A
VO > 5V
mV
%
1.5
Output Voltage Change with
Temperature
Long Term Stability
(Note 4)
Full Temperature Range
%
%
%
TJ = 125OC, VIN – VOUT = 40V,
after 1000hr
0.3
1
Output Noise Voltage
0.003
10Hz ≤ f ≤ 10KHz, TJ = 25°C
VIN – VOUT ≤ 40V
3.5
50
10
Minimum Load Current
Adjustment Pin Current
mA
µA
IADJ
100
Adjustment Pin Current
Change
3V ≤ VIN – VOUT ≤ 40V
10mA ≤ IOUT ≤ 1.2A
3V ≤ VIN – VOUT ≤ 40V,
10mA ≤ IOUT ≤ 1.5A, P ≤ 15W
0.2
5.0
1.3
∆IADJ
µA
V
Reference Voltage
1.2
1.25
Note 1: All characteristics are measured with a 0.1µF capacitor across the input and a 1µF capacitor across the output.
Note 2: Input regulation is expressed here as the percentage change in output voltage per 1V change at the input.
Note 3: Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately.
Note 4: Since long-term drift cannot be measured on the individual devices prior to shipment, this specification is not intended to
be a guarantee or warranty. It is an engineering estimate of the average drift to be expected from lot to lot.
4