VMIVME-5565 Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts
Physical/Environmental Specifications
Power Requirements:
+5VDC (±5 percent), 5.0A maximum
Temperature:
Operating: 0 to +65° C with forced air cooling
Storage: -40 to +85° C
Relative Humidity:
20% to 80%, noncondensing
MTBF:
163,995 hours (Bellcore)
Data Transfers
Data written into the Reflective Memory is broadcast to all
nodes on the network without further involvement of the
sending or receiving nodes. Data is transferred from memory
locations on the sending nodes to corresponding memory
locations on the receiving nodes.
An illustration of a network example using Reflective Memory is
shown in Figure 1.
Trademarks
Windows and Windows NT are registered trademarks of
Microsoft Corporation. Other registered trademarks are the
property of their respective owners.