欢迎访问ic37.com |
会员登录 免费注册
发布采购

70G-IDC24S 参数 Datasheet PDF下载

70G-IDC24S图片预览
型号: 70G-IDC24S
PDF下载: 下载PDF文件 查看货源
内容描述: 触点闭合DC输入模块 [Contact Closure DC Input Modules]
分类和应用:
文件页数/大小: 2 页 / 112 K
品牌: GRAYHILL [ GRAYHILL, INC ]
 浏览型号70G-IDC24S的Datasheet PDF文件第2页  
Contact Closure DC Input Modules
FEATURES
• Wire Dry Contact Sensors Directly
to Module, Eliminate External
Power Supply
• 2500 Vac Isolation
• Built-In Status LED
• UL, CSA, CE Mark, TÜV Certified
(TÜV not available on OpenLine
®
)
• Simplifies Field Wiring
70L-IDL
70G-IDC
CIRCUITRY: Negative True Logic
G5
+
1
VDC
I/O MODULE
PIN #
+
1
1
FILTER
OPTICAL
ISOLATION
OpenLine
®
TYPICAL WIRING FOR MODULE 0
6
A
7
HYSTERESIS
INPUT
DEVICE
2
Vcc
CH. A STATUS
GND
TRANSFORMER
ISOLATION
2
CONTACT
DEBOUNCE
5
2
+
+VCC
3
OUTPUT
4
GROUND
5
10KΩ
OUTPUT
DRIVER
CIRCUIT
+
DC
SUPPLY
INPUT
DEVICE
3
3
FILTER
OPTICAL
ISOLATION
B
HYSTERESIS
8
CH. B STATUS
TERMINAL
BLOCK #
4
BASE
OR
RACK
4
9
MODULE
0Ω
MODULE ID
SPECIFICATIONS:
Specifications apply over operating
temperature range unless noted otherwise.
OpenLine
®
Vibration:
.15mm, 10 to 50 Hz per IEC68-2-6
Mechanical Shock:
50 G's, 0.5 mS, sinsoidal
per IEC68-2-27
Storage Temperature Range:
-40°C to +100°C
Operating Temperature Range:
-40°C to +85°C
per MIL–STD–202, Method 213, Condition F
Storage Temperature Range:
-40°C to +125°C
Operating Temperature Range:
0°C to +60°C
All Modules
Output Specifications
Output Current Range:
1-50 mA
Breakdown Voltage:
50 Vdc minimum
Off State Leakage Current:
1 µA maximum
On State Voltage Drop:
0.45 Vdc at 50 mA
maximum
I/O Modules
G5
Vibration:
20 G's peak or .06" double amplitude
10–2000 Hz per MIL–STD–202, Method 204,
Condition D
Mechanical Shock:
1500 G's 0.5 mS half-sine
Available from your local Grayhill Distributor.
For prices and discounts, contact a local Sales
Office, an authorized local Distributor or Grayhill.
General Characteristics
Isolation Voltage Field to Logic:
2500 Vac (rms) minimum
SPECIFICATIONS: By Part Number
Type/Function
G5, Dry Contact
Specifications
Maximum Dry Contact Voltage Rating
Minimum Dry Contact Current Rating
Maximum Turn-on Time
Maximum Turn-off Time
Contact Resistance (Output Low)
Contact Resistance (Output High)
Nominal Logic Voltage (Vcc)
Logic Voltage Range: G5
Max. Logic Supply Current
@ Nominal Vcc
1
Grayhill Part Number
70L-IDC5S
Units
Vdc
mA
mSec
mSec
Vdc
Vdc
mA
25
5
10
10
1.25K
25K
5
4.5-5.5
120
1
25
5
3.0
3.0
1.25K
25K
5
4.5-6
41
25
5
3.0
3.0
1.25K
25K
24
15-30
41
70G-IDC5S
70G-IDC24S
WHEN BOTH CHANNELS ARE ACTIVATED
I/O
20
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com