GS88237BB/D-333/300/250/200
DC Electrical Characteristics
Parameter
Input Leakage Current
(except mode pins)
ZZ Input Current
Output Leakage Current
Output High Voltage
Output High Voltage
Output Low Voltage
Symbol
I
IL
I
IN1
I
OL
V
OH2
V
OH3
V
OL
Test Conditions
V
IN
= 0 to V
DD
V
DD
≥
V
IN
≥
V
IH
0 V
≤
V
IN
≤
V
IH
Output Disable, V
OUT
= 0 to V
DD
I
OH
=
–8
mA, V
DDQ
= 2.375 V
I
OH
=
–8
mA, V
DDQ
= 3.135 V
I
OL
= 8 mA
Min
–1
uA
–1
uA
–1
uA
–1
uA
1.7 V
2.4 V
—
Max
1 uA
1 uA
100 uA
1 uA
—
—
0.4 V
Operating Currents
-333
Parameter
Test Conditions
Mode
Symbol
0
to
70°C
380
55
-300
0
to
70°C
345
50
-250
0
to
70°C
290
40
-200
0
to
70°C
240
30
–40
to
85°C
390
55
–40
to
85°C
355
50
–40
to
85°C
300
40
–40
to
85°C
250
30
Unit
Operating
Current
3.3 V
Operating
Current
2.5 V
Standby
Current
Deselect
Current
Device Selected;
All other inputs
≥V
IH
or
≤
V
IL
Output open
Device Selected;
All other inputs
≥V
IH
or
≤
V
IL
Output open
ZZ
≥
V
DD
– 0.2 V
Device Deselected;
All other inputs
≥
V
IH
or
≤
V
IL
(x36)
Pipeline
I
DD
I
DDQ
mA
(x36)
Pipeline
I
DD
I
DDQ
I
SB
I
DD
380
55
390
55
345
05
355
50
290
40
300
40
240
30
250
30
mA
—
Pipeline
40
50
40
50
40
50
40
50
mA
—
Pipeline
85
90
80
85
85
90
75
80
mA
Notes:
1. I
DD
and I
DDQ
apply to any combination of V
DD3
, V
DD2
, V
DDQ3
, and V
DDQ2
operation.
2. All parameters listed are worst case scenario.
Rev: 1.04 3/2005
13/29
© 2002, GSI Technology