www.hamlin.com
55100 Miniature Flange Mount Hall Effect Proximity Sensor
Features
●
Magnetically operated position sensor
●
Digital, latching or programmable analogue
types available
●
Medium, high or programmable sensitivities
●
3 wire (voltage output) or 2 wire (current
output) versions
●
Reverse/Over voltage protection
●
Built in temperature compensation
Benefits
High switching speed up to 10kHz
Long life; up to 20 billion operations
Unaffected by harsh environments
Operates in static or dynamic magnetic
field
●
Customer selection of cable length and
connector type
●
●
●
●
Applications
●
●
●
●
●
●
Position and limit sensing
RPM measurement
Flow metering
Commutaion of brushless dc motors
Angle sensing
Magnetic encoders
DIMENSIONS (in) mm
BLOCK DIAGRAM
Notes:
1) Add capcitor Cn as
shown, close to the
sensor, for transient
suppression if required.
2) Add resistor Rpu as
shown for sinking output
SPECIFICATIONS
Digital Switch or Digital Latch
Hall Type
Supply Voltage (Note 1)
Absolute Ratings
Operate
Overvoltage Protection
Output High Voltage
Output Low Voltage
Output Current (continuously on)
Current Consumption Over
Temperature Range
Switching Speed
Temperature
Operating
Storage
Low
High
Vdc
Vdc
Vdc - max.
Vdc
Vdc - max.
mA - max.
mA
mA
mA
°C
°C
3 Wire (Voltage Output)
-15 to +28
+3.8 to +24
32
Sinking output
0.4 @ 10mA
10
1.6 - 5.2
1.6 - 5.2
10
-40 to +100
-65 to +105
Digital Switch or Digital Latch
2 Wire (Current Output)
-15 to +28
+3.75 to +24
32
N/A
N/A
N/A
5 - 6.9
12 - 17
10
-40 to +100
-65 to +105
A - Analogue
(Programmable Only) (Note 2)
8.5
4.5 - 5.5
19.5
4.65
0.35
-1.0 to +1.0
2 - 10
2 - 10
2
-40 to +100
-65 to +105
Note 1: As long as Tj (Junction Temperature max. Is not exceeded.
Note 2: Preprogrammed by Hamlin or Customer pending agreement.
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 1
HALL OPTIONS
ACTIVATE DISTANCES ARE APPROXIMATE
USING
N
E
F
E
B
MAGNET
(.827l x .276W x .185H) 21 x 7 x 4.7
HAMLIN P/N 5812334000
TABLE 2
Cable Length:-
(Cable Type 24AWG 7/32 PVC 105°
C
UL 1430/UL1569)
TABLE 3
Termination Options:-
SELECT OPTION
DESCRIPTION (2 WIRE VERSION ILLUSTRATED
Tinned Leads
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
(in) mm
A
Select Hall Option
2M
2H
2L
3M
3H
3L
AP
Hall Type
2 Wire Switch
2 Wire Switch
2 Wire Latch
3 Wire Switch
3 Wire Switch
3 Wire Latch
Analog
Sensitivity Gauss
(typ.)
120
57
40
130
59
86
Programmable
Activate - d (in)
mm
(.531) 13,5
(.728) 18,5
(.827) 21,0
(.492) 12,5
(709) 18,0
(.394) 10,0
Consult Hamlin
01
02
03
04
05
(3.94) 100
(11.81) 300
(19.69) 500
(29.53) 750
(39.37)
1000
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch
ORDERING INFORMATION
55100
Series 55100
Hall Option
Cable Length
Termination
Hamlin USA
Hamlin Europe
Hamlin China
XX
XX
X
Table 1
Table 2
Table 3
Tel: +1 920 648 3000
•
Fax: +1 920 648 3001
•
Email: sales.us@hamlin.com
Tel: +44 (0)1603 257700
•
Fax: +44 (0)1603 257702
•
Email: sales.uk@hamlin.com
Tel: +86 (0) 512 69365 800
•
Fax: +86 (0) 512 69365 811
•
Email: sales.cn@hamlin.com
DRGNo: 55100XXXXX REV : AG Date:9/6/12 DCR: B9016