欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAC203P-P033BCEIE 参数 Datasheet PDF下载

HAC203P-P033BCEIE图片预览
型号: HAC203P-P033BCEIE
PDF下载: 下载PDF文件 查看货源
内容描述: 通用AC输入谐波校正AC- DC热插拔低电压的CompactPCI PENTA输出200瓦有源均流开关电源 [UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HOT-SWAP LOW VOLTAGE CompactPCI PENTA OUTPUT 200 WATTS ACTIVE CURRENT SHARING SWITCHING POWER SUPPLIES]
分类和应用: 开关输出元件输入元件PC
文件页数/大小: 2 页 / 319 K
品牌: HITRON [ HITRON ELECTRONICS CORPORTION ]
 浏览型号HAC203P-P033BCEIE的Datasheet PDF文件第2页  
H HiTRON
UNIVERSAL AC INPUT HARMONIC CORRECTION
AC-DC HOT-SWAP LOW VOLTAGE CompactPCI
PENTA OUTPUT 200 WATTS ACTIVE CURRENT SHARING
SWITCHING POWER SUPPLIES HAC203P SERIES
FEATURES:
200W 3U X 9HP EUROCARD PACKAGE
MEET IEC 61000-3-2 HARMONIC
CORRECTION
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
HOT-SWAPPABLE
THIRD-WIRE CURRENT SHARING
EMI MEET EN 55022 / FCC CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Typ. 90-264Vac.
Power Factor Correction:
Meet Harmonic Correction
IEC 61000-3-2.Power Factor typ. 0.97-0.98.
Input Connector:
Positronic 47-pin PCIH47M400A1.
Input Frequency:
47-63Hz.
Inrush Current:
8.66Arms @ 230Vac.
Input Current:
2.5A @115Vac/1.18A @230Vac.
Dielectric Withstand:
Meet IEC 60950-1 regulation.
EMI:
Meet EN 55022 / FCC Class A.
Hold-up Time:
18.4mS @115Vac, 20.8mS @230Vac.
Earth Leakage:
Less than 0.64mA @230Vac.
Remote ON/OFF:
Available at [INH#] & [EN#] pins.
Status LED:
<Green> means valid input voltage.
<Amber> means a critical fault.
Thermal Protection (OTP):
Installed NTC and thermostat for
thermal sensor at [DEG#] pin.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typ. 200W continuous.
Output Connector:
Positronic 47-pin PCIH47M400A1.
Line Regulation:
Typ. 0.2%.
Load Regulation:
Typ. ±1%.
Noise & Ripple:
Typ. 1% peak to peak or 55mV,
whichever is greater.
OVP:
Built-in at all outputs.
Adjustability:
Available at VO1,2,3 & 4.
Remote Sensing:
Available at VO1,VO2,VO3 & VO4.
Hot-Swap:
Available.
N+1 Redundancy:
Installed with internal OR-ing diodes
at all outputs for N+1 redundancy operation.
Current Sharing:
Third-wire current sharing at VO1,2,3 & 4.
Over Current Protection (OCP):
Installed at each rail.
DC OK:
Available at VO1,2,3,4 & 5.
Overload Protection (OLP):
Fully protected against output
overload or short circuit. Typical 120-150% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency:
Typ. 67-69 %.
Switching Frequency:
133K Hz.
Circuit Topology:
Forward circuit.
Transient Response:
Peak transient less than 50mV and
recovers within 0.96mS after 25% load-change.
Safety Standard:
IEC 60950-1 Class I.
Construction:
Eurocard 3U X 9HP X 185mm
CompactPCI format.
Operating Temperature:
-5 to +50 °C at full load with
specified air flow. Derates linearly to 50% at +60 °C.
Storage Temperature:
-40 to +85 °C.
Temperature Coefficient:
Typ. ±0.02% / °C.
Cooling:
At least 14CFM moving air is required to achieve
full rating power 200W in a confined area.
Power Density:
2.85 Watts/ Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-3-