H HiTRON
03/26/08
UNIVERSAL INPUT AC-DC OPEN FRAME DUAL OUTPUT 8 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVI08 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
COMPACT 4x2x0.92 INCH PCB FORMAT
DUAL CONVETERS ARCHITECTURE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Range typ. 90-264Vac.
Rating 100 to 240Vac.
Input Connector:
V-M connector.
Input Frequency:
47-63Hz.
Inrush Current:
2.9A rms @ 230Vac 50Hz.
Input Current:
Typ. 0.12A@115Vac, 0.066A@230Vac.
Dielectric Withstand:
Meet IEC 60950-1.
EMI:
Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time:
Typ. 30.4mS @115Vac, 154.mS @ 230Vac.
Leakage Current:
0.67mA for IEC60950 Touch Current.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
V-M connector.
Output Wattage:
Typ. 8 watts.
Line Regulation:
Typ. 0.1%.
Load Regulation:
Main VO1 typ. ±0.6%.
Aux. VO2 typ. ±0.6%.
Total Regulation:
Main VO1 typ. ±0.6%.
Aux. VO2 typ. ±0.6%.
Noise & Ripple:
Typ. 1.0% peak to peak.
OVP:
Built-in at VO1 & VO2(Clamp).
Adjustability:
Available at VO1 and VO2.
Overload Protection (OLP):
Fully protected against outputs overload and short circuit.
Typ. OLP set at 125-150% of rating output power.
Consult the factory for OLP setting.
Operating Temperature:
-40°C to +85 °C under forced
air flow for full load..
Storage Temperature:
-40 to +85°C.
Temperature Coefficient:
Typ. 0.04%/°C.
Cooling:
Free air convection.
Construction:
4”x2”x0.92” PCB format.
Power Density:
1.35Watts / Cubic Inch.
GENERAL SPECIFICATION
Efficiency:
Typ. 63.7%. (Various with output voltage).
Switching Frequency:
82KHz.
Circuit Topology:
Fixed frequency flyback circuit.
Dual converters for floating output.
Transient Response:
Output voltage returns in less than
0.1mS following a 25% load change.
Safety Standard:
IEC 60950-1 Class I.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application.