H HiTRON
UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE &
MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING
POWER SUPPLIES HVI102 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
LOW-PROFILE U-BRACKET FORMAT
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Range typ. 90-264Vac.
Rating 100 to 240Vac.
Input Connector:
V-M connector.
Input Frequency:
47-63Hz.
Inrush Current:
≤30.6A
peak @230Vac.
Input Current:
Typ. 1.8A @115Vac, 0.8A @230Vac.
Dielectric Withstand:
Meet IEC 60950-1.
EMI:
Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time:
Typ. 11mS @115Vac, 60mS @ 230Vac.
Power Fail Signal:
Installed.
Earth Leakage:
Less than 0.4mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
V-M connector.
Output Wattage:
Typ. 100 watts.
Line Regulation:
Typ. 0.1%.
Load Regulation:
Main VO1 typ. ±1-2%.
Aux.VO2/VO3/VO4 typ. ± 3-5% (Common choke).
Noise & Ripple:
Typ. 1.0% peak to peak.
OVP:
Built-in at main output.
UVP:
Built-in at main output.
Remote Sensing:
Installed in main output VO1.
Adjustability:
Available at main output VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
Operating Temperature:
0 to +50 °C under forced air flow
for full load.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. 0.04%/°C.
Cooling:
At least 25 cfm direct forward air flow is
required to achieve full rating power.
Construction:
U-bracket format.
GENERAL SPECIFICATION
Efficiency:
Typ. 80-82%.
Switching Frequency:
63K Hz.
Circuit Topology:
Fixed frequency forward circuit.
Transient Response:
Output voltage returns in
less than 3mS following
a 25% load change.
Safety Standard:
IEC 60950-1/UL 60950-1 Class I.
Power Density:
4.10Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.