欢迎访问ic37.com |
会员登录 免费注册
发布采购

HVP348-T033EI 参数 Datasheet PDF下载

HVP348-T033EI图片预览
型号: HVP348-T033EI
PDF下载: 下载PDF文件 查看货源
内容描述: 通用输入谐波校正AC- DC N + 1冗余和带风扇的三路输出的有功电流共享密封盒350瓦内部开关 [UNIVERSAL INPUT HARMONIC CORRECTION AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING ENCLOSURE BOX WITH FAN TRIPLE OUTPUT 350 WATTS INTERNAL SWITCHING]
分类和应用: 风扇开关输出元件瞄准线输入元件
文件页数/大小: 2 页 / 259 K
品牌: HITRON [ HITRON ELECTRONICS CORPORTION ]
 浏览型号HVP348-T033EI的Datasheet PDF文件第2页  
H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING
ENCLOSURE BOX WITH FAN TRIPLE OUTPUT 350 WATTS INTERNAL
SWITCHING POWER SUPPLIES HVP348 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
NO MINIMUM LOAD REQUIREMENT
MEET IEC 61000-3-2 HARMONIC CORRECTION
N+1 REDUNDANCY & OR-ING DIODES
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN 55022 CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Universal 90-264Vac with PFC.
Input Connector:
Molex Mini-Fit (F-M) 42404-06A1.
Input Frequency:
47-63Hz.
Inrush Current:
Typ. 25A @230Vac(Active circuit).
Input Current:
Typ. 5.4A @115Vac, 1.7A@ 230Vac.
Dielectric Withstand:
Meet IEC 60950-1.
EMI:
Meet CISPR EN 55022 Class B.
Hold-up Time:
Typ. 38mS @ 115Vac & 230Vac.
Power Fail Signal:
Indicated by LEDs.
Power Factor Correction & Harmonic Correction:
Meet IEC 61000-3-2, PF typ. 0.97-0.98 @ full load.
Remote Inhibit/Power Disable:
Installed.
Earth Leakage:
Less than 0.85 mA.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
Molex Mini-Fit (F-M) 42404-24A1.
Output Wattage:
Typ. 350 Watts.
Line Regulation:
Typ. 0.1%.
Load Regulation:
Independent & fully regulated Magnetic
Amplifier outputs. VO1/VO2/VO3 typ. ±1.0%.
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Available at VO1,VO2 & VO3 (Latch circuit).
Redundancy:
Available for N+1 redundancy & OR-ing
diodes built-in at all rails.
Current Sharing:
Third-wire load sharing at VO1,2,3.
Adjustability:
Available at VO1,VO2 & VO3.
Over Current Protection (OCP):
Installed in output
VO1,VO2 and VO3.
Over Temp. Protection (OTP):
By thermostat.
Overload Protection (OLP):
Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
Operating Temperature:
0 to +50°C.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
0.04%/°C.
Cooling:
Internal cooling fan installed.
Construction:
Enclosure box installed with internal
cooling fan.
Hot Swappable (Insertion):
Installed.
GENERAL SPECIFICATION
Efficiency:
Typ. 75-78.0%.
Switching Frequency:
60K Hz.
Circuit Topology:
PWM fixed-frequency forward circuit.
Transient Response:
Output voltage returns in less than
3ms following a 25% load change.
Safety Standard:
UL 60950-1/EN 60950-1 Class I.
Power Density:
2.8Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-57-