PDF下载: 下载PDF文件 查看货源
内容描述: 低成本,不锈钢,隔离式压力传感器 [Low Cost, Stainless Steel, Isolated Pressure Sensors]
分类和应用: 传感器压力传感器
文件页数/大小: 8 页 / 630 K
品牌: HONEYWELL-ACC [ HONEYWELL ACCELEROMETERS ]
 浏览型号19CPSIPG4K的Datasheet PDF文件第1页浏览型号19CPSIPG4K的Datasheet PDF文件第2页浏览型号19CPSIPG4K的Datasheet PDF文件第3页浏览型号19CPSIPG4K的Datasheet PDF文件第5页浏览型号19CPSIPG4K的Datasheet PDF文件第6页浏览型号19CPSIPG4K的Datasheet PDF文件第7页浏览型号19CPSIPG4K的Datasheet PDF文件第8页  
19 mm Series
Notes:
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]). This
parameter is not 100% tested and is guaranteed by process design and tested on a sample basis only. Temperature
coefficient of span is evaluated using a 1 mA constant current excitation source.
PHYSICAL DIMENSIONS (For reference only: mm [in].)
Package 1 (see note): Cell Package
Note:
Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of the
sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
Package 3: Flush Mount with Flange
4 Honeywell