欢迎访问ic37.com |
会员登录 免费注册
发布采购

ASCX05DN 参数 Datasheet PDF下载

ASCX05DN图片预览
型号: ASCX05DN
PDF下载: 下载PDF文件 查看货源
内容描述: 微观压力传感器 [Microstructure Pressure Sensors]
分类和应用: 传感器换能器压力传感器
文件页数/大小: 4 页 / 319 K
品牌: HONEYWELL [ HONEYWELL SOLID STATE ELECTRONICS CENTER ]
 浏览型号ASCX05DN的Datasheet PDF文件第1页浏览型号ASCX05DN的Datasheet PDF文件第2页浏览型号ASCX05DN的Datasheet PDF文件第4页  
Microstructure Pressure Sensors
Signal Conditioned
0 psi to 1 psi up to 0 psi to 150 psi
ASCX PERFORMANCE CHARACTERISTICS
(4)
Characteristic
Offset
(5)
Models ASCX15/30/100/150xN
Models ASCX01/05DN
Output @ FS Pressure
Combined Pressure Linearity and Hysteresis
(6)
Temperature Effect on Span 0 °C to 70 °C [32
°F
to 158
°F]
(7)
Models ASCX15/30/100/150xN
Models ASCX01/05DN
Temperature Effect on Offset 0 °C to 70 °C [32
°F
to 158
°F]
(7)
Models ASCX15/30/100/150xN
Models ASCX01/05DN
Repeatability
(8)
Response Time
(9)
Min.
0.205
0.180
Typ.
0.250
0.250
4.750
±0.1
±0.2
±0.2
±0.5
±0.5
±0.2
100
Max.
0.295
0.320
±0.5
±1.0
±1.5
±1.0
±1.5
±0.5
ASCX Series
Unit
Volts
Volts
Volts
% FSO
% FSO
% FSO
% FSO
% FSO
% FSO
Microsec.
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Note 4:
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Maximum pressure above which causes permanent sensor failure.
Sensitivity is ratiometric to supply voltage.
Performance specs are shown at reference conditions. Specifications apply for absolute pressure devices with pressure applied
to Port A. For gage devices, pressure is applied to Port B and Port A is left open for ambient. For differential pressures, Port B
is the high-pressure port. All differential devices feature dual pressure ports and can be used as gage or differential sensors.
For absolute devices, Port B is inactive.
Offset calibration is at the lowest pressure for each given device.
Linearity refers to the best straight line fit as measured for offset, full scale and �½ full-scale pressure.
Temperature errors are the maximum shift over 0 °C to 70 °C [32
°F
to 158
°F],
relative to the 25 °C [77
°F]
reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C
[32
°F
to 158
°F]
after:
a) 100 temperature cycles, 0 °C to 70 °C [32
°F
to 158
°F]
b) 1.0 million pressure cycles, 0 psi to Full-Scale Span.
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
ELECTRICAL CONNECTION
Pinout
ASCX Series
PIN 1) External Offset Adjustment
PIN 2) V
s
PIN 3) + Output
PIN 4) Ground
PIN 5) N/C
PIN 6) Do Not Use
Honeywell
Sensing and Control 3