Temperature Sensors
HEL-700 Series
Platinum RTDs
FEATURES
HEL-700Serieselementsarefullyassem-
bled, ready to use directly or in probe
assemblies without the need for fragile
splices to extension leads.
ɀ Linear resistance vs temperature
ɀ Accurate and Interchangeable
ɀ Excellent stability
ɀ Teflon or fiberglass lead wires
ɀ Wide temperature range
ɀ Ceramic case material
The 1000ȉ, 375 alpha version, provides
10X greater sensitivity and signal-to-
noise. Optional NIST calibrations im-
prove accuracy to ±0.03°C at 0°C.
TYPICAL APPLICATIONS
ɀ HVAC – room, duct and refrigerant
equipment
ɀ Instrument and probe assemblies –
temperature compensation
ɀ Process control – temperature
regulation
ORDER GUIDE
Fig. 1: Wheatstone Bridge 2-Wire Interface
HEL-705
HEL-707
HEL-711
HEL-712
HEL-716
HEL-717
28 ga. TFE Teflon, 2-wire only
28 ga. Fiberglass, 2-wire only
28 ga. TFE Teflon (2-wire 1000ȉ, 3-wire 100ȉ)
28 ga. Fiberglass (2-wire 1000ȉ, 3-wire 100ȉ)
24 ga. TFE Teflon (2-wire 1000ȉ, 3-wire 100ȉ)
24 ga. Fiberglass (2-wire 1000ȉ, 3-wire 100ȉ)
-U 1000ȉ, 0.00375 ȉ/ȉ/°C
-T
100ȉ, 0.00385 ȉ/ȉ/°C DIN Standard
-0
-1
±0.2% Resistance Trim (Standard)
±0.1% Resistance Trim (Optional)
-12 Lead wire length, 12 inches
-00 No NIST calibration
Fig. 2: Linear Output Voltage
-C1 NIST @ 0°C
-C2 NIST @ 0 & 100°C
-C3 NIST @ 0, 100 & 260°C
MOUNTING DIMENSIONS (for reference only)
Fig. 3: Adjustable Point (Comparator) Interface
CAUTION
PRODUCT DAMAGE
Theinherentdesignofthiscomponentcausesittobesensitive
to electrostatic discharge (ESD). To prevent ESD-induced
damage and/or degradation, take normal ESD precautions
when handling this product.
Honeywell ɀ MICRO SWITCH Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
87