Table 1. SS351AT/SS451A Specifications (At Vs=3.0 Vdc to 24 Vdc, 20 mA load, T
A
= -40 °C to 150 °C [-40 °F to 257 °F])
Characteristic
Condition
Minimum
Typical
Maximum
Unit
1
Supply voltage :
SS451A
-40 °C to 150 °C [-40 °F to 302 °F]
3
–
24
Vdc
SS351AT
-40 °C to 125 °C [-40 °F to 257 °F]
3
–
24
SS351AT
150 °C [302 °F]
3
–
12
Supply current
Vsupply = 5 V at 25 °C [77 °F]
–
4.5
6
Vsupply = 3 V at 25 °C [77 °F]
–
3.5
5
mA
–
–
9
Output Current
–
–
–
20.0
mA
Vsat
at 20 mA, gauss > Bop positive
–
–
0.4
V
or gauss < Bop negative
Output leakage current
gauss > Bop+ or < Bop-
–
–
10
µA
Output switching time:
Vsupply = 12 V at 25 °C [77 °F],
rise
–
–
1.5
µs
R
L
=1.6 KOhm, C
L
= 20 pF
fall
–
–
1.5
Thermal resistance:
SS451A
–
–
233
–
°C/W
SS351AT
–
303
–
SS351AT/SS451A:
Operate positive
–
35
85
135
gauss
Operate negative
-135
-85
-35
SS351AT/SS451A:
Release positive
–
10
50
120
gauss
Release negative
-120
-50
-10
SS351AT/SS451A
gauss
Differential
–
5
35
80
Operating temperature
–
-40 [-40]
–
150 [302]
°C [°F]
Storage temperature
–
-40 [-40]
–
150 [302]
°C [°F]
Note 1:
See Figure 1.
Table 2. SS351AT/SS451A Absolute Maximum Ratings
1
Characteristic
Minimum
Typical
Maximum
Unit
Supply voltage
-28.0
–
28.0
V
Applied output voltage
-0.5
–
28.0
V
Output current
–
–
20
mA
Magnetic flux
–
–
no limit
gauss
Note 1:
The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified
in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a
uniform magnetic field.
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Figure 1. SS351AT Rated Supply Voltage
Figure 2. Current Sinking Output Block Diagram
2
www.honeywell.com/sensing