Figure 2. Transfer Function Limits
100
90
Figure 3. Completed Catalog Listing Example
Output (%V
supply
)
80
70
60
50
40
30
20
10
0
Pressure
Output (V) = 0.8 x V
supply
x (Pressure
applied
– P
min.
) + 0.10 x V
supply
P
max.
– P
min.
SSCSANN100PGAA3
SIP package, AN pressure
port, no diagnostics, 100
psi gage, analog output,
10% to 90% calibration at
3.3 Vdc.
P
min.
Table 5. Pressure Types
Pressure Type
Description
Output is proportional to the difference between applied pressure and a built-in reference to vacuum.
Absolute
P
min.
is set at absolute zero pressure (full vacuum).
Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2)
Differential
50% point of transfer function set at Port 1 = Port 2.
Output is proportional to the difference between applied pressure and atmospheric (ambient)
Gage
pressure. P
min.
is set at atmospheric pressure.
Table 6
.
Pressure Range Specifications for 1 psi to 150 psi
Pressure Range
Order Code
P
min.
015PA
030PA
060PA
100PA
150PA
001PD
005PD
015PD
030PD
060PD
001PG
005PG
015PG
030PG
060PG
100PG
150PG
0 psi
0 psi
0 psi
0 psi
0 psi
-1 psi
-5 psi
-15 psi
-30 psi
-60 psi
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
P
max.
15 psi
30 psi
60 psi
100 psi
150 psi
1 psi
5 psi
15 psi
30 psi
60 psi
1 psi
5 psi
15 psi
30 psi
60 psi
100 psi
150 psi
Over-
16
pressure
Absolute
30 psi
60 psi
120 psi
250 psi
250 psi
Differential
10 psi
30 psi
30 psi
60 psi
120 psi
Gage
10 psi
30 psi
30 psi
60 psi
120 psi
250 psi
250 psi
Burst
17
Pressure
Common Mode
18
Pressure
Long-term
Stability
(1000 hr,
25 C [77 F])
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
P
max.
60 psi
120 psi
240 psi
250 psi
250 psi
10 psi
40 psi
60 psi
120 psi
240 psi
10 psi
40 psi
60 psi
120 psi
240 psi
250 psi
250 psi
NA
NA
NA
NA
NA
150 psi
150 psi
150 psi
150 psi
250 psi
150 psi
150 psi
150 psi
150 psi
250 psi
250 psi
250 psi
Honeywell Sensing and Control
5