Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
2.1 Maximum Rating
DC voltage
AC voltage
VDC
Vpp
12
10
V
V
Between any terminals
Between any terminals
+25℃
2.2 Electrical Characteristics
Characteristics of channel 1 (switching input pin 2 connected to ground pin 3)
Source impedance
Load impedance
Item
Insertion attenuation
Reference level
Zs=50Ω
Z
L
=2kΩ//3pF
Freq
min
40.40MHz
11.6
38.0
38.0
34.0
36.0
35.0
33.0
T
A
=25℃
typ
14.1
45.0
45.0
44.0
45.0
42.0
40.0
-72
max
16.6
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
ppm/k
33.90MHz
38.40MHz
Relative attenuation
41.90MHz
32.40MHz
25.00~38.40MHz
Sidelobe
41.90~45.00MHz
Temperature coefficient
Characteristics of channel 2 (switching input pin 2 connected to input pin 1)
Source impedance
Load impedance
Item
Insertion attenuation
Reference level
Zs=50Ω
Z
L
=2kΩ//3pF
Freq
min
33.40MHz
33.05MHz
32.90MHz
32.40MHz
38.90MHz
34.47MHz
30.90MHz
40.40MHz
40.90MHz
41.40MHz
12.9
-1.9
-1.6
-1.6
35.0
24.0
30.0
32.0
32.0
32.0
T
A
=25℃
typ
15.4
-0.4
-0.1
-0.1
45.0
32.0
40.0
40.0
45.0
40.0
max
17.9
1.1
1.4
1.4
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Relative attenuation
2