8
Sw itching Specifications
TA = 25°C, VCC = 5.0 V, Unless Otherwise Specified.
Parameter
Sym.
Device
Min.
Typ. Max. Units
Test Conditions
Fig.
Note
Propagation Delay
Time to Logic Low
at Output
HCPL-0370/3700
4.0
tPHL
15.0
40.0
µs
µs
RL = 4.7 kΩ, CL = 30 pF
10
HCPL-3760
4.5
7, 10
Propagation Delay
Time to Logic High
at Output
HCPL-0370/3700
10.0
tPLH
RL = 4.7 kΩ, CL = 30 pF
RL = 4.7 kΩ, CL = 30 pF
11
HCPL-3760
8.0
20
HCPL-0370/3700
Output Rise Time
(10-90%)
tr
µs
µs
HCPL-3760
14
8
HCPL-0370/3700
0.3
Output Fall Time
(90-10%)
tf
RL = 4.7 kΩ, CL = 30 pF
IIN = 0 mA, RL = 4.7 kΩ,
HCPL-3760
0.4
Common Mode
Transient Immunity
at Logic High Output
| CMH|
| CML|
4000
V/µs
V/µs
V
= 2.0 V, VCM = 1400 V
O min
9, 11 12, 13
Common Mode
HCPL-0370/3700
HCPL-3760
IIN = 3.11 mA RL = 4.7 kΩ,
VO max = 0.8 V,
Transient Immunity
at Logic Low Output
600
IIN = 1.56 mA VCM = 140 V
Package Characteristics
Over Recommended Temperature TA = 0°C to 70°C, Unless Otherwise Specified.
Parameter
Sym. Min. Typ.[9] Max. Units
Conditions
Fig. Note
Input-Output Momentary
Withstand Voltage*
Option 020
V
ISO
3750
V rms RH ≤ 50%, t = 1 min;
TA = 25°C
16,
17
18
5000
Input-Output Resistance
Input-Output Capacitance
RI-O
CI-O
1012
0.6
Ω
V
I-O = 500 Vdc
16
pF
f = 1 MHz; VI-O = 0 Vdc
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if
applicable), your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”