10
Switching Specifications (AC)
Over Recommended Operating Conditions T
A
= 0°C to 70°C, V
CC
= 3 V to 18 V, unless otherwise specified.
Parameter
Propagation
Delay Time
to Logic Low
at Output
Propagation
Delay Time
to Logic High
Output
Symbol
t
PHL
Device
HCPL-
Min.
Typ.* Max. Units
65
3
t
PLH
70
34
4701/4731
070A/073A
1,000 10,000
500
25
30
500
60
90
130
V/µs
µs
µs
Test Conditions
I
F
= 40
µA,
R
L
= 11 to 16 kΩ,
V
CC
= 3.3 to 5 V
I
F
= 0.5 mA,
T
A
= 25°C
R
L
= 4.7 kΩ
I
F
= 40
µA,
R
L
= 11 to 16 kΩ,
V
CC
= 3.3 to 5 V
I
F
= 0.5 mA,
T
A
= 25°C
R
L
= 4.7 kΩ
I
F
= 0 mA, R
L
= 4.7 to 11 kΩ,
V
CM
= 10 V
p-p
,
T
A
= 25°C,
Fig. Note
7, 9 9, 10
7, 9 9, 10
Common Mode |CM
H
|
Transient
Immunity at
Logic High
Output
Common Mode |CM
L
|
Transient
Immunity at
Logic Low
Output
8
6, 7
1,000 10,000
V/µs
2,000
I
F
= 0.5 mA, R
L
= 4.7 to 11 kΩ,
|V
CM
| = 10 V
p-p
,
T
A
= 25°C
I
F
= 40
µA,
R
L
= 11 to 16 kΩ,
|V
CM
| = 10 V
p-p
V
CC
= 3.3 to 5 V, T
A
= 25°C
8
6, 7
*All typical values at T
A
= 25°C and V
CC
= 5 V, unless otherwise noted.
Package Characteristics
Parameter
Input-Output Momentary
Withstand Voltage**
Option 020
Resistance
(Input-Output)
Capacitance
(Input-Output)
Insulation Leakage
Current (Input-Input)
Resistance (Input-Input)
Capacitance
(Input-Input)
R
I-O
C
I-O
I
I-I
R
I-I
C
I-I
4731
073A
4731
073A
Device
Symbol HCPL- Min. Typ.* Max. Units
V
ISO
4701
4731
2500
5000
10
12
0.6
0.005
10
11
0.03
0.25
pF
µA
pF
f = 1 MHz
5
V rms
Test Conditions
RH
50%,
t = 1 min.,
T
A
= 25°C
V
I-O
= 500 VDC
RH
45%
f = 1 MHz
RH
45%, t = 5 s,
V
I-I
= 500 VDC
Fig. Note
3, 4
3, 4a
3
3
5
*All typical values at T
A
= 25°C and V
CC
= 5 V.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if appli-
cable), your equipment level safety specification or Agilent Application Note 1074 entitled “Optocoupler Input-Output Endurance
Voltage.”