2
Device Selection Guide
Typical
Viewing
Angle
2θ
1
/
2
(Deg.)
[4]
Color and
Dominant
Wavelength
(nm), Typ.
[3]
Luminous
Intensity Iv (mcd)
[1,2]
@ 20 mA
Min.
Max.
4200
4200
4200
4200
4200
HLMP-EL10-WZ000
5500
7200
7200
7200
7200
7200
7200
HLMP-EL10-X1000
HLMP-EJ10-WZ000
HLMP-EJ10-X1000
HLMP-EJ10-Y2000
HLMP-EH10-UX000
HLMP-EH10-VY000
HLMP-EH10-WZ000
HLMP-EH10-X1000
HLMP-EH10-Y2000
7200
5500
7200
9300
3200
4200
5500
7200
9300
4200
HLMP-EG10-VY000
HLMP-EG10-WZ000
HLMP-EG10-X1000
4200
5500
7200
9300
9300
HLMP-EG10-Y2000
9300
12000
12000
9300
9300
9300
16000
16000
16000
16000
12000
12000
21000
21000
16000
21000
27000
9300
12000
16000
21000
21000
7200
12000
16000
21000
16000
21000
27000
Lamps Without Standoffs
on Leads
(Outline Drawing A)
HLMP-EL08-VY000
HLMP-EL08-VYK00*
HLMP-EL08-VXK00*
HLMP-EL08-VX400**
HLMP-EL08-VX000
HLMP-EL08-WZ000
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL10-VY000
Amber 590
HLMP-EL08-XZ400**
HLMP-EL08-XZ000
HLMP-EL08-XZK00*
HLMP-EL08-XY000
HLMP-EL08-XYK00*
HLMP-EL08-X1K00*
HLMP-EL08-X1000
6°
[5]
Orange 605
HLMP-EJ08-WZ000
HLMP-EJ08-X1000
HLMP-EJ08-Y2000
HLMP-EH08-UX000
HLMP-EH08-VY000
Red-Orange 615
HLMP-EH08-WZ000
HLMP-EH08-X1000
HLMP-EH08-Y2000
HLMP-EG08-VW000
HLMP-EG08-VY000
HLMP-EG08-WZ000
Red 626
HLMP-EG08-X1000
HLMP-EG08-YZ000
HLMP-EG08-Y1000
HLMP-EG08-Y2000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in
bold
are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.