TJ49150
ELECTRICAL CHARACTERISTICS
Limits in standard typeface are for TJ=25℃, and limits in
boldface
type apply over the
full operating temperature range.
Unless otherwise specified: V
BIAS
= V
O(NOM.)
+ 2.1V, V
IN
= V
O(NOM.)
+ 1V, V
EN
=V
BIAS
, I
L
= 10 mA.
PARAMETER
Adjustable Pin Voltage
Line Regulation
(Note 1)
Load Regulation
(Note 1, 2)
SYMBOL
V
ADJ
ΔV
LINE
ΔV
LOAD
TEST CONDITION
V
OUT
+1 V < V
IN
< 5.5 V
V
OUT
+1 V < V
IN
< 5.5 V
10 mA < I
L
< 1.5 A
I
L
= 0.75 A
Dropout Voltage
(Note 2)
V
DROP
I
L
= 1.5 A
Dropout Voltage
(Note 2)
Dropout Voltage
(Note 3)
Bias Pin Current
Ground Pin Current
(Note 4)
Ground Pin Current
(Note 4)
Current Limit
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
Logic Low
Enable threshold
(Note 5)
Logic High
Enable Pin Input Current
(Note 5)
Adjust Pin Current
Note 1.
V
ENH
I
EN
I
ADJ
Output = High
V
EN
= V
BIAS
V
ADJ
= 0.8 V
2.0
0.1
0.1
1.0
1.0
V
μA
μA
V
DROP
V
DROP
I
BIAS
I
GND1
I
GND2
I
CL
T
SD
ΔT
SD
V
ENL
Output = Low
I
L
= 1.5 A , V
BIAS
= 5.0 V
I
L
= 1.5 A
I
L
= 1.5 A
I
L
= 10 mA
V
EN
< 0.2 V
240
200
1.5
300
300
0.1
2.5
155
30
0.4
MIN.
0.784
0.776
TYP.
0.8
0.02
0.25
120
MAX.
0.816
0.824
0.1
1.0
160
200
320
400
270
340
2.1
450
600
450
600
0.5
1.0
UNIT
V
%/V
%
mV
mV
V
μA
μA
μA
A
°C
°C
V
Note 2.
Note 3.
Note 4.
Note 5.
Output voltage line regulation is defined as the change in output voltage from the nominal value due to change in the input line
voltage. Output voltage load regulation is defined as the change in output voltage from the nominal value due to change in load
current.
Regulation is measured at constant junction temperature by using a 10ms current pulse. Devices are tested for load regulation in
the load range from 10mA to 1.5A.
For V
OUT
≤ 1.0V, the V
BIAS
Dropout specification does not apply due that the minimum V
BIAS
input is 3.0V.
I
GND
= I
BIAS
+ (I
IN
– I
OUT
). The total current drawn from the supply is the sum of the load current plus the ground current.
SOP-8/SOP-8-PP packages only.
July 2011
6
HTC