RELATIVE HUMIDITY SENSOR
HS1101LF
Meets RoHS regulations
Based on a unique capacitive cell, these relative humidity sensors are designed for high
volume, cost sensitive applications such as
office automation, automotive cabin air
control, home appliances, and industrial process control systems.
They are also useful
in all applications where humidity compensation is needed.
M
AIN FEATURES
●
Lead free components
●
Full interchangeability
with no calibration required in standard conditions
●
Instantaneous desaturation
after long periods in saturation phase
●
Compatible with automatized assembly processes,
including Pb free
wave soldering and reflow processes
(1)
●
High reliability and long term stability
●
Patented solid polymer structure
●
Suitable for linear voltage or frequency output circuitry
●
Fast response time and very low temperature coefficient
●
Part may be washed with distilled water.
●
Individual marking for compliance to stringent traceability requirements
(1)
soldering temperature profiles available on request / contact us at
application@humirel.com
Operating Range
100
M
AXIMUM RATINGS
Ratings
Operating Temperature
Storage Temperature
Supply Voltage (Peak)
Humidity Operating Range
Symbol
Ta
Tstg
Vs
RH
Value
-60 to 140
-60 to 140
10
0 to 100
Unit
Relative Humidity in % RH
90
80
°C
°C
Vac
% RH
70
60
50
40
30
20
10
0
-60
-40
-20
0
20
40
60
80
100
120
140
160
Temperature in °C
C
HARACTERISTICS
Humidity sensor
(Ta = 25°C, measurement frequency @ 10kHz / 1V unless otherwise noted)
Characteristics
Humidity measuring range
Supply voltage
Nominal capacitance @ 55% RH*
Temperature coefficient
Averaged Sensitivity from 33% to 75% RH
Leakage current (Vcc = 5 Volts)
Recovery time after 150 hours of condensation
Humidity Hysteresis
Long term stability
Time constant (33 to 80 % RH, still air @ 63%)
Deviation to typical response curve (10% to 90%) RH)
τ
ta
+/-0.5
3
+/-2
5
Symbol
RH
Vs
C
Tcc
∆C
/% RH
I
tr
Min.
1
Typ.
Max.
99
10
Unit.
%RH
V
pF
pF/°C
pF/% RH
177
180
183
0.01
0.31
1
10
+/-1
nA
s
%RH
%RH/yr
s
%RH
*tighter specification available on request
HUMIREL HPC052 Rev.E April 2007
TECHNICAL 1 DATA
HS1101LF