Power Supply option of HTG3400 Series at 5V
DC
Continuous Mode:
When powering HTG3400 series modules at 5V
DC
in continuous mode, an initial 3-minute stabilization time (t
s
) is
necessary to reach the temperature and the RH outputs with an optimum accuracy.
Pulsed Mode:
When powering HTG3400 series modules in pulsed mode, accurate temperature and RH measurement is reached
instantaneously. Time up (T
up
) must be of 5% of the cycle time. Minimum time up (T
up
) is 150 ms. Thus minimium
cycle time is 3s.
Supply Voltage (V)
T
up
= 5% of
cycle time
Vcc = 5V
Time
Cycle time
Power Supply option of HTG3400 Series at 3.3V
DC
At 3.3V
DC
power supply, there is no measurable impact of type of powering on temperature and RH accuracy.
________________________________________________________________________________________
Humirel HTG3400 Series Datasheet / HPC124 Rev A November 2007
2