HY57V161610D
AC CHARACTERISTICS
Paramter
(TA=0°C to 70°C, V
DD
=3.0V to 3.6V, V
SS
=0V
Note1,2
))
-5
Symbol
Min
Max
Min
55
55
16.5
100K
38.5
3
2
1
0
1
4
2
0
2
3
1
1
64
64
100K
Max
Min
60
60
18
40
3
2
1
0
1
4
2
0
2
3
1
1
-
Max
-
-
-
100K
-
-
-
-
-
-
-
-
-
-
-
-
64
Min
70
70
20
45
3
2
1
0
1
4
2
0
2
3
1
1
-
Max
-
-
-
100K
-
-
-
-
-
-
-
-
-
-
-
-
64
ns
ns
ns
ns
CLK
CLK
CLK
CLK
CLK
CLK
CLK
CLK
CLK
CLK
CLK
CLK
ms
3
-55
-6
-7
Unit
Note
Operation
RAS cycle time
Auto Refresh
RAS to CAS delay
RAS active time
RAS precharge time
RAS to RAS bank active delay
CAS to CAS bank active delay
Write command to data-in delay
Data-in to precharge command
Data-in to active command
DQM to data-in Hi-Z
DQM to data mask
MRS to new command
Precharge to data output Hi-Z
Power down exit time
Self refresh exit time
Refresh Time
tRC
tRRC
tRCD
tRAS
tRP
tRRD
tCCD
tWTL
tDPL
tDAL
tDQZ
tDQM
tMRD
tPROZ
tPDE
tSRE
tREF
55
55
15
40
3
2
1
0
1
4
2
0
2
3
1
1
Rev. 4.0/Aug. 02
9