欢迎访问ic37.com |
会员登录 免费注册
发布采购

X24C01MM 参数 Datasheet PDF下载

X24C01MM图片预览
型号: X24C01MM
PDF下载: 下载PDF文件 查看货源
内容描述: 串行E2PROM [Serial E2PROM]
分类和应用: 内存集成电路光电二极管可编程只读存储器电动程控只读存储器电可擦编程只读存储器时钟
文件页数/大小: 14 页 / 275 K
品牌: ICMIC [ IC MICROSYSTEMS ]
 浏览型号X24C01MM的Datasheet PDF文件第2页浏览型号X24C01MM的Datasheet PDF文件第3页浏览型号X24C01MM的Datasheet PDF文件第4页浏览型号X24C01MM的Datasheet PDF文件第5页浏览型号X24C01MM的Datasheet PDF文件第7页浏览型号X24C01MM的Datasheet PDF文件第8页浏览型号X24C01MM的Datasheet PDF文件第9页浏览型号X24C01MM的Datasheet PDF文件第10页  
X24C01  
Figure 6. ACK Polling Sequence  
Acknowledge Polling  
The disabling of the inputs can be used to take advantage  
of the typical 5 ms write cycle time. Once the stop  
WRITE OPERATION  
COMPLETED  
ENTER ACK POLLING  
condition is issued to indicate the end of the host’s write  
operation the X24C01 initiates the internal write cycle.  
ACK polling can be initiated immediately. This involves  
issuing the start condition followed by the word address  
for a write operation. If the X24C01 is still busy with the  
write operation no ACK will be returned. If the X24C01  
ISSUE  
START  
has completed the write operation an ACK will be  
returned and the controller can then proceed with the  
next read or write operation.  
ISSUE SLAVE  
ADDRESS AND R/W = 0  
ISSUE STOP  
READ OPERATIONS  
Read operations are initiated in the same manner as  
write operations with exception that the R/W bit of the  
ACK  
RETURNED?  
NO  
word address is set to a one. There are two basic read  
operations: byte read and sequential read.  
YES  
It should be noted that the ninth clock cycle of the read  
operation is not a “don’t care.” To terminate a read  
NEXT  
OPERATION  
A WRITE?  
operation, the master must either issue a stop condition  
during the ninth cycle or hold SDA HIGH during the ninth  
NO  
clock cycle and then issue a stop condition.  
YES  
ISSUE STOP  
PROCEED  
Byte Read  
To initiate a read operation, the master sends a start  
condition followed by a seven bit word address and a  
read bit. The X24C01 responds with an acknowledge and  
then transmits the eight bits of data. The read  
PROCEED  
operation is terminated by the master; by not responding  
with an acknowledge and by issuing a stop condition.  
3837 FHD F11  
Refer to Figure 7 for the start, word address, read bit,  
acknowledge and data transfer sequence.  
Figure 7. Byte Read  
S
T
A
R
T
S
T
WORD  
ADDRESS n  
BUS ACTIVITY:  
MASTER  
O
P
SDA LINE  
S
P
A
C
K
L
S
B
M
S
B
R
/
BUS ACTIVITY:  
X24C01  
DATA n  
W
3837 FHD F12  
6