X25097
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias ................... –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on any Pin with
Respect to V
SS
................................... –1V to +7V
D.C. Output Current.............................................. 5mA
Lead Temperature
(Soldering, 10 seconds).............................. 300
°
C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
0°C
–40°C
Supply Voltage
X25097
X25097-2.7
X25097-1.8
Limits
4.5V to 5.5V
2.7V to 5.5V
1.8V to 3.6V
7038 FRM T05
Min.
Max.
+70°C
+85°C
7038 FRM T04
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions, unless otherwise specified.)
Limits
Symbol
I
CC1
I
CC2
I
SB
I
LI
I
LO
V
IL
(1)
V
IH
(1)
V
OL1
V
OL2
V
OL3
V
OH1
V
OH2
V
OH3
Parameter
V
CC
Supply Current (Write)
V
CC
Supply Current (Read)
V
CC
Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output LOW Voltage
Output LOW Voltage
Output HIGH Voltage
Output HIGH Voltage
Output HIGH Voltage
Min.
Max.
3
400
1
10
10
Units
mA
µ
A
µ
A
µ
A
µ
A
V
V
V
V
V
V
V
V
Test Conditions
SCK = V
CC
x 0.1/V
CC
x 0.9 @ 5MHz,
SO = Open, CS =
V
SS
SCK = V
CC
x 0.1/V
CC
x 0.9 @ 5MHz,
SO = Open, CS =
V
SS
CS = V
CC
, V
IN
=
V
SS
or V
CC
V
IN
=
V
SS
to V
CC
V
OUT
=
V
SS
to V
CC
–0.5
V
CC
x 0.7
V
CC
x 0.3
V
CC
+ 0.5
0.4
0.4
0.4
V
CC
> 3.3V, I
OL
= 2.1mA
2V < V
CC
≤
3.3V, I
OL
= 1mA
V
CC
≤
2V, I
OL
= 0.5mA
V
CC
> 3.3V, I
OH
= -1.0mA
2V < V
CC
≤
3.3V, I
OH
= -0.4mA
V
CC
≤
2V, I
OH
= -0.25mA
7038 FRM T06
V
CC
– 0.8
V
CC
– 0.4
V
CC
– 0.2
POWER-UP TIMING
Symbol
t
PUR
(2)
t
PUW
(2)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
Max.
1
5
ms
ms
Units
7038 FRM T07
Notes:
(1) V
IL
Min. and V
IH
Max. are for reference only and are not 100% tested.
(2) t
PUR
and t
PUW
are the delays required from the time V
CC
is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
8