X25642
Operational Notes
The X25642 powers-up in the following state:
• The device is in the low power standby state.
• A HIGH to LOW transition on CS is required to enter
an active state and receive an instruction.
• SO pin is high impedance.
• The “write enable” latch is reset.
Data Protection
The following circuitry has been included to prevent in-
advertent writes:
• The “write enable” latch is reset upon power-up.
• A WREN instruction must be issued to set the “write
enable” latch.
• CS must come HIGH at the proper clock count in or-
der to start a write cycle.
Figure 1. Read E
2
PROM Array Operation Sequence
CS
0
SCK
1
2
3
4
5
6
7
8
9
10
20 21 22 23 24 25 26 27 28 29 30
INSTRUCTION
SI
16 BIT ADDRESS
15 14 13
3
2
1
0
DATA OUT
HIGH IMPEDANCE
SO
7
MSB
3132 ILL F03.1
6
5
4
3
2
1
0
Figure 2. Read Status Register Operation Sequence
CS
0
SCK
1
2
3
4
5
6
7
8
9
10 11 12 13 14
INSTRUCTION
SI
DATA OUT
HIGH IMPEDANCE
SO
7
MSB
6
5
4
3
2
1
0
3132 ILL F04
5