欢迎访问ic37.com |
会员登录 免费注册
发布采购

ICS477R-05LF 参数 Datasheet PDF下载

ICS477R-05LF图片预览
型号: ICS477R-05LF
PDF下载: 下载PDF文件 查看货源
内容描述: 四PLL VCXO与高清电视 [Quad PLL with VCXO for HDTV]
分类和应用: 晶体外围集成电路石英晶振压控振荡器电视光电二极管时钟
文件页数/大小: 7 页 / 148 K
品牌: ICS [ INTEGRATED CIRCUIT SYSTEMS ]
 浏览型号ICS477R-05LF的Datasheet PDF文件第1页浏览型号ICS477R-05LF的Datasheet PDF文件第2页浏览型号ICS477R-05LF的Datasheet PDF文件第3页浏览型号ICS477R-05LF的Datasheet PDF文件第5页浏览型号ICS477R-05LF的Datasheet PDF文件第6页浏览型号ICS477R-05LF的Datasheet PDF文件第7页  
ICS477-05
Quad PLL with VCXO for HDTV
External Capacitor =
2 x (centering error)/(trim sensitivity)
Trim sensitivity is a parameter which can be supplied by
your crystal vendor. If you do not know the value,
assume it is 30 ppm/pF. After any changes, repeat the
measurement to verify that the remaining error is
acceptably low (typically less than ±25 ppm).
PCB Layout Recommendations
For optimum device performance and lowest output
phase noise, the following guidelines should be
observed.
1) The 0.01µF decoupling capacitors should be
mounted on the component side of the board as close
to the VDD pins as possible. No vias should be used
between the decoupling capacitors and VDD pins. The
PCB trace to VDD pin should be kept as short as
possible, as should the PCB trace to the ground via.
2) The external crystal should be mounted just next to
the device with short traces. The X1 and X2 traces
should not be routed next to each other with minimum
spaces, instead they should be separated and away
from other traces.
3) To minimize EMI, the 33Ω series termination resistor
(if needed) should be placed close to the clock output.
4) An optimum layout is one with all components on the
same side of the board, minimizing vias through other
signal layers. Other signal traces should be routed
away from the ICS477-05. This includes signal traces
just underneath the device, or on layers adjacent to the
ground plane layer used by the device.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS477-05. These ratings,
which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Storage Temperature
Junction Temperature
Soldering Temperature
7V
Rating
-0.5 V to VDD+0.5 V
0 to +70°C
-40 to +85°C
-65 to +150°C
125°C
260°C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
-40
+3.15
Typ.
+3.3
Max.
+85
+3.45
Units
°C
V
MDS 477-05 H
Integrated Circuit Systems, Inc.
4
525 Race Street, San Jose, CA 95126
Revision 062404
tel (408) 297-1201
www.icst.com