IC61LV256
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
–40°C to +85°C
Speed
8, 10, 12
15
All
V
CC
3.3V, +10%, –5%
3.3V
±
10%
3.3V + 10%, –5%
DC ELECTRICAL CHARACTERISTICS
(Over Operating Range)
Symbol Parameter
V
OH
V
OL
V
IH
V
IL
I
LI
I
LO
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
(1)
Input Leakage
Output Leakage
GND
≤
V
IN
≤
V
CC
GND
≤
V
OUT
≤
V
CC
, Outputs Disabled
Com.
Ind.
Com.
Ind.
Test Conditions
V
CC
= Min., I
OH
= –4.0 mA
V
CC
= Min., I
OL
= 8.0 mA
Min.
2.4
—
2.2
–0.3
–1
–5
–1
–5
Max.
—
0.4
V
CC
+ 0.3
0.8
1
5
1
5
Unit
V
V
V
V
µA
µA
Notes:
1. V
IL
(min.) = –0.3V (DC); V
IL
(min.) = –2.0V (pulse width
≤
2.0 ns).
V
IH
(max.) = V
CC
+ 0.5V (DC); V
IH
(max.) = Vcc + 2.0V (pulse width
≤
2.0 ns).
2. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
-8 ns
Sym. Parameter
I
CC
I
SB
1
Vcc Dynamic Operating
Supply Current
TTL Standby Current
(TTL Inputs)
CMOS Standby
Current (CMOS Inputs)
Test Conditions
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = f
MAX
V
CC
= Max.,
V
IN
= V
IH
or V
IL
CE
≥
V
IH
, f = 0
V
CC
= Max.,
CE
≤
V
CC
– 0.2V,
V
IN
≥
V
CC
– 0.2V, or
V
IN
≤
0.2V, f = 0
Com.
Ind.
Com.
Ind.
Com.
Ind.
Min. Max.
-10 ns
Min. Max.
-12 ns
Min. Max.
-15 ns
Min. Max.
Unit
— 120
— 130
— 25
— 30
— 2
— 5
— 110
— 120
— 25
— 30
— 2
— 5
— 100
— 110
— 25
— 30
— 2
— 5
— 90
— 100
— 25
— 30
— 2
— 5
mA
mA
I
SB
2
mA
Notes:
1. At f = f
MAX
, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE
(1,2)
Symbol
C
IN
C
OUT
Parameter
Input Capacitance
Output Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Max.
6
5
Unit
pF
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: T
A
= 25°C, f = 1 MHz, Vcc = 3.3V.
4
Integrated Circuit Solution Inc.
AHSR027-0B