IS61C512
READ CYCLE SWITCHING CHARACTERISTICS(1) (Over Operating Range)
-15 ns
Min.
15
—
3
-20 ns
Min.
20
—
3
-25 ns
Max.
-35 ns
Symbol Parameter
Max.
—
15
—
15
15
7
Max.
—
20
—
20
20
8
Min.
25
—
3
Min.
Max.
—
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tRC
Read Cycle Time
—
25
—
25
25
9
35
—
3
tAA
Address Access Time
Output Hold Time
CE1 Access Time
CE2 Access Time
OE Access Time
35
—
tOHA
tACE1
tACE2
tDOE
—
—
—
0
—
—
—
0
—
—
—
0
—
—
—
0
35
35
12
—
(2)
tLZOE
OE to Low-Z Output
OE to High-Z Output
—
6
—
9
—
10
—
—
10
—
20
(2)
tHZOE
0
0
0
0
12
—
tLZCE1(2) CE1 to Low-Z Output
2
—
—
8
3
—
—
9
3
3
tLZCE2(2) CE2 to Low-Z Output
2
3
3
3
—
(2)
tHZCE
CE1 or CE2 to High-Z Output
0
0
0
0
12
—
(3)
tPU
CE1 or CE2 to Power-Up
0
—
12
0
—
18
0
0
(3)
tPD
CE1 or CE2 to Power-Down
—
—
—
—
20
Notes:
1. Test conditions assume signal transition times of 5 ns or less, timing reference levels of 1.5V, input pulse levels of 0 to 3.0V
and output loading specified in Figure 1a.
2. Tested with the load in Figure 1b. Transition is measured ±500 mV from steady-state voltage. Not 100% tested.
3. Not 100% tested.
AC TEST CONDITIONS
Parameter
Input Pulse Level
Input Rise and Fall Times
Unit
0V to 3.0V
3 ns
Input and Output Timing
and Reference Level
1.5V
Output Load
See Figures 1a and 1b
AC TEST LOADS
1213 Ω
1213 Ω
3.3V
3.3V
OUTPUT
OUTPUT
1378 Ω
1378 Ω
100 pF
Including
jig and
5 pF
Including
jig and
scope
scope
Figure 1a.
Figure 1b.
4
Integrated Circuit Solution Inc.
SR011-0B