Life Expectancy
Failure quota
>60000 with VAC, >200000 With WVDC applied at +70°C
>30000 with VAC, >100000 With WVDC applied at +85°C
>10000 with 0.8xVAC, >30000 With 0.8xWVDC applied at +100°C
300/billion component hours
Test Condition
Temperature= +40°C
+2°C
Relative Humidity=93
+2%
Test length= 56 days
Performance requirements
Max Capacitance
change
DF Change
Insulation resistance
< +3%% of initially
measured valued
< 200% of initially
specified valued
> 50% of minimum
specified value
Damp Heat Test
Resistance to soldering Heat
Solder bath temperature: +260°C +/- 5°C
Exposure time: 10 seconds +/- 1 second
Max Capacitance
change
DF Change
Insulation resistance
<1% of initially measured value
Construction
Electrodes
Coating
Lead terminations
< .1% at 1kHz
>50% of minimum specified value
Metallized Polypropylene film
Vacuum deposited Metal layers
Flame retardant Solvent resistant plastic case with epoxy end fill
Lead free tinned copper leads