IMP707C/D 参数 Datasheet PDF下载

IMP707C/D图片预览
型号: IMP707C/D
PDF下载: 下载PDF文件 查看货源
内容描述: 低功耗μP监控电路 [LOW-POWER レP SUPERVISOR CIRCUITS]
分类和应用: 监控
文件页数/大小: 9 页 / 167 K
品牌: IMP [ IMP, INC ]
 浏览型号IMP707C/D的Datasheet PDF文件第1页浏览型号IMP707C/D的Datasheet PDF文件第2页浏览型号IMP707C/D的Datasheet PDF文件第3页浏览型号IMP707C/D的Datasheet PDF文件第5页浏览型号IMP707C/D的Datasheet PDF文件第6页浏览型号IMP707C/D的Datasheet PDF文件第7页浏览型号IMP707C/D的Datasheet PDF文件第8页浏览型号IMP707C/D的Datasheet PDF文件第9页  
IMP705/6/7/8, 8 13L
Pin Descriptions
Pin Number
IMP705/706
IMP707/708
IMP813L
DIP/SO MicroSO DIP/SO MicroSO DIP/SO MicroSO Name
1
2
3
4
5
3
4
5
6
7
1
2
3
4
5
3
4
5
6
7
1
2
3
4
5
3
4
5
6
7
MR
V
CC
GND
PFI
PFO
Function
Manual RESET input. The active LOW input triggers a reset
pulse. A 250µA pull-up current allows the pin to be driven
by TTL / CMOS logic or shorted to ground with a switch.
+5V power supply input.
Ground reference for all signals.
Power-fail voltage monitor input. With PFI less than
1.25V, PFO goes low. Connect PFI to ground or V
CC
when not used.
Power-fail output. The output is active LOW and sinks
current when PFI is less than 1.25V.
Watchdog input. WDI controls the internal watchdog
timer. A HIGH or LOW signal for 1.6sec at WDI
allows the internal timer to run-out, setting WDO LOW.
The watchdog function is disabled by floating WDI or
by connecting WDI to a high-impedance three-state
buffer. The internal watchdog timer clears when:
RESET is asserted; WDI is three-stated; or WDI sees
a rising or falling edge.
Not connected.
Active-LOW reset output. Pulses LOW for 200ms
when triggered, and stays low whenever V
CC
is below
the reset threshold (IMP705: 4.65V, IMP705J: 4.00V,
IMP706: 4.40V). RESET remains LOW for 200ms
after V
CC
rises above the RESET threshold or MR
goes from LOW to HIGH. A watchdog timeout will not
trigger RESET unless WDO is connected to MR.
Watchdog output. WDO pulls LOW when the 1.6 sec
internal watchdog timer times-out and does not go
HIGH until the watchdog is cleared. In addition, when
V
CC
is below the reset threshold, WDO remains low.
Unlike RESET, WDO does not have a minimum pulse
width and as soon as V
CC
exceeds the reset
threshold, WDO goes HIGH with no delay.
Active-HIGH reset output. RESET is the inverse of
RESET. The IMP813L has only a RESET output.
6
8
6
8
WDI
6
NC
7
1
7
1
RESET
8
2
8
2
WDO
8
2
7
1
RESET
Feature Summary
IMP705
Power-fail detector
Brownout detection
Manual RESET input
Power-up/down RESET
Watchdog timer
Active-HIGH RESET output
Active-LOW RESET output
RESET threshold
4
IMP706
I
I
I
I
I
I
4.40V
IMP707
I
I
I
I
I
I
4.65V
IMP708
I
I
I
I
I
I
4.40V
IMP813L
I
I
I
I
I
I
4.65V
©
1999 IMP, Inc.
I
I
I
I
I
I
4.65V/4.00V