Magnetic Characteristics
PRG Pin Connected to V
S
Parameter
Operate Points
Release Points
Hysteresis
1)
Symbol
B
OPS
B
OPN
B
RPS
B
RPN
B
HYS
Limit Values
Min.
typ.
max.
3.5
5
7
–7
–5
–3.5
2.2
4
6
–6
–4
–2.2
0.2
1
2
Unit
mT
mT
mT
mT
mT
Notes
1)
1)
Positive magnetic fields are related to the approach of a magnetic south pole to the branded side of package
PRG Pin Connected to GND
Parameter
Operate Points
Release Points
Hysteresis
1)
Symbol
B
OPS
B
OPN
B
RPS
B
RPN
B
HY
Limit Values
Min.
typ.
max.
2.2
4
6
-6
-4
-2.2
3.5
5
7
-7
-5
-3.5
0.2
1
2
Unit
mT
mT
mT
mT
mT
Notes
1)
1)
Positive magnetic fields are related to the approach of a magnetic south pole to the branded side of package
Note: The listed AC/DC and magnetic characteristics are ensured over the operating range
of the integrated circuit. Typical characteristics specify mean values expected over
the production spread. If not other specified, typical characteristics apply at
T
j
= 25 °C
and
V
S
= 2.7 V.
Data Sheet
6