Data Sheet TLE 6230 GP
Electrical Characteristics
Parameter and Conditions
V
S
= 4.5 to 5.5 V ;
T
j
= - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
1. Power Supply, Reset
Symbol
Values
min
Unit
typ
max
Supply Voltage
4
Supply Current (outputs ON)
5
Supply Current (outputs OFF)
5
Minimum Reset Duration
2. Power Outputs
V
S
I
S(ON)
I
S(OFF)
t
Reset,min
T
J
= 25°C
T
J
= 150°C
R
DS(ON)
V
DS(AZ)
I
D(lim)
V
Reset
= L
V
bb
=12V
I
D
= 0.5 A, resistive load
I
D
= 0.5 A, resistive load
I
D(lkg)
t
ON
t
OFF
V
INL
V
INH
V
INHys
I
IN(1..4)
I
IN(PRG,Res)
I
IN(SI,SCLK)
I
IN(CS)
I
SOH
= 2 mA
I
SOL
= 2.5 mA
V
SOH
V
SOL
I
SOlkg
V
FAULTL
4.5
--
--
10
--
1
1
--
5.5
2
2
--
V
mA
mA
µs
ON Resistance
V
S
= 5 V
; I
D
= 500 mA
Output Clamping Voltage
Current Limit
Output Leakage Current
Turn-On Time
Turn-Off Time
3. Digital Inputs
--
--
40
1
--
--
--
0.8
--
--
1.5
--
8
6
1
1.7
55
2
5
12
10
Output OFF
V
A
µA
µs
µs
Input Low Voltage
Input High Voltage
Input Voltage Hysteresis
Input Pull Down/Up Current (IN1 ... IN4)
PRG, Reset Pull Up Current
Input Pull Down Current (SI, SCLK)
Input Pull Up Current (
CS
)
4. Digital Outputs (SO,
FAULT
)
SO High State Output Voltage
- 0.3
2.0
50
20
20
10
10
--
--
100
50
50
20
20
1.0
--
200
100
100
50
50
V
V
mV
µA
µA
µA
µA
V
S
- 0.4 --
--
0.4
10
0.4
V
V
µA
V
SO Low State Output Voltage
--
-10
--
--
0
--
Output Tri-state Leakage Current
CS
= H, 0
V
SO
V
S
FAULT Output Low Voltage
I
FAULT
= 1.6 mA
4
For V
S
< 4.5V the power stages are switched according the input signals and data bits or are definitely switched
off. This undervoltage reset gets active at V
S
= 3V (typ. value) and is guaranteed by design.
5
For Reset = H.
V2.1