A10-DATASHEET
2015.12.31
HPS Power Supply Operating Conditions
9
Symbol
Description
Condition
(15)
Minimum
(13)
Typical
Maximum
Unit
V
CCH_GXB[L,R]
Transceiver high voltage power
supply
—
1.710
1.8
1.890
V
Related Information
•
on page 26
Provides the data rate ranges for different transceiver speed grades.
•
on page 23
Provides the data rate ranges for different transceiver speed grades.
•
HPS Power Supply Operating Conditions
Table 6: HPS Power Supply Operating Conditions for Arria 10 SX Devices—Preliminary
This table lists the steady-state voltage and current values expected from Arria 10 system-on-a-chip (SoC) devices with ARM
®
-based hard processor system
(HPS). Power supply ramps must all be strictly monotonic, without plateaus. Refer to Recommended Operating Conditions for Arria 10 Devices table for
the steady-state voltage values expected from the FPGA portion of the Arria 10 SoC devices.
Symbol
Description
Condition
Minimum
(17)
Typical
Maximum
(17)
Unit
V
CCL_HPS
HPS core voltage and periphery
circuitry power supply
HPS processor speed =
1.2 GHz
HPS processor speed =
1.5 GHz, –1 speed grade
3.0 V
2.5 V
1.8 V
0.87
0.92
2.85
2.375
1.71
0.9
0.95
3.0
2.5
1.8
0.93
0.98
3.15
2.625
1.89
V
V
V
V
V
V
CCIO_HPS
HPS I/O buffers power supply
(15)
(16)
(17)
These data rate ranges vary depending on the transceiver speed grade. Refer to Transceiver Performance for Arria 10 GT Devices table for exact data
rate ranges.
28.3 Gbps is the maximum data rate for GT channels. 17.4 Gbps is the maximum data rate for GX channels.
This value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements. Refer to the
PDN tool for the additional budget for the dynamic tolerance requirements.
Altera Corporation
Arria 10 Device Datasheet