CV-51002
2015.12.04
Recommended Operating Conditions
5
Recommended Operating Conditions
Table 3: Recommended Operating Conditions for Cyclone V Devices
This table lists the steady-state voltage values expected from Cyclone V devices. Power supply ramps must all be strictly monotonic, without plateaus.
Symbol
Description
Condition
Minimum
(2)
Typical
Maximum
(2)
Unit
V
CC
Devices without
Core voltage, periphery circuitry power
internal scrubbing
supply, transceiver physical coding
feature
sublayer (PCS) power supply, and
transceiver PCI Express
®
(PCIe
®
) hard IP Devices with internal
scrubbing feature (with
digital power supply
SC suffix)
(3)
Auxiliary supply
I/O pre-driver power supply
—
3.3 V
3.0 V
2.5 V
1.07
1.1
1.13
V
1.12
1.15
1.18
V
V
CC_AUX
V
CCPD
(4)
2.375
3.135
2.85
2.375
2.5
3.3
3.0
2.5
2.625
3.465
3.15
2.625
V
V
V
V
(2)
(3)
(4)
The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements.
Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
The SEU internal scrubbing feature is available for Cyclone V E, GX, SE, and SX devices with the "SC" suffix in the part number. For device
availability and ordering, contact your local Altera sales representatives.
V
CCPD
must be 2.5 V when V
CCIO
is 2.5, 1.8, 1.5, 1.35, 1.25, or 1.2 V. V
CCPD
must be 3.0 V when V
CCIO
is 3.0 V. V
CCPD
must be 3.3 V when V
CCIO
is
3.3 V.
Altera Corporation