DC/DC C
ONVERTERS
DUAL OUTPUTS
PARAMETER
OUTPUT
VOLTAGE
OUTPUT
CURRENT
OUTPUT
POWER
OUTPUT
RIPPLE
INPUT
VOLTAGE
INPUT
CURRENT
INPUT REFL.
RIPPLE
EFFICIENCY
CONDITION
MIN
HR152-2812
TYP
MAX
HR152-2815
MIN
TYP
MAX
HR150 SERIES
20 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin (12 VDC for 12V models), 100% load, unless otherwise specified.
UNITS
VDC
±11.88 ±12.00 ±12.12
0
—
0 TO 1 MHz
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
0 TO 2 MHz
—
18
—
—
—
75
—
—
30
28
—
—
25
79
±625
15
50
36
50
35
50
—
±14.85 ±15.00 ±15.15
0
—
—
18
—
—
—
75
—
—
30
28
—
—
25
79
±500
15
50
36
50
35
50
—
mA
W
mV p-p
VDC
V
mA
mA p-p
%
TRIPLE OUTPUTS
PARAMETER
OUTPUT
VOLTAGE
OUTPUT
CURRENT
OUTPUT
POWER
OUTPUT
RIPPLE
INPUT
VOLTAGE
INPUT
CURRENT
INPUT REFL.
RIPPLE
EFFICIENCY
CONDITION
FULL
LOAD
MAIN
DUAL
MIN
HR153-1212
TYP
MAX
HR153-1215
MIN
TYP
MAX
MIN
HR153-2812
TYP
MAX
MIN
HR153-2815
TYP
MAX
UNITS
VDC
4.95
5.00
5.05
±11.88 ±12.00 ±12.12
100
—
—
—
—
—
—
10
—
—
—
76
—
—
—
—
—
40
20
12
—
—
50
79
2000
±208
10
2.5
15
80
40
16
25
60
100
—
4.95
5.00
5.05
4.95
5.00
5.05
4.95
5.00
5.05
±14.85 ±15.00 ±15.15 ±11.88 ±12.00 ±12.12 ±14.85 ±15.00 ±15.15
100
—
—
—
—
—
—
10
—
—
—
76
—
—
—
—
—
40
20
12
—
—
50
79
2000
±167
10
2.5
15
80
40
16
25
60
100
—
100
—
—
—
—
—
—
18
—
—
—
75
—
—
—
—
—
40
20
28
—
—
40
79
2000
±208
10
2.5
15
80
40
36
50
50
80
—
100
—
—
—
—
—
—
18
—
—
—
75
—
—
—
—
—
40
20
28
—
—
40
79
2000
±167
10
2.5
15
80
40
36
50
50
80
—
MAIN
1
DUAL
MAIN
±DUAL
TOTAL
MAIN
0 TO 1 MHz
DUAL
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
0 TO 2 MHz
mA
W
mV p-p
VDC
V
mA
mA p-p
%
Note 1. Minimum load required for full output capability on auxiliary outputs. Minimum current can be reduced when dual outputs are used at reduced loads.
B4-45