HR150 SERIES
20 WATT
DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin (12 VDC for 12V models), 100% load, unless otherwise specified.
DUAL OUTPUTS
PARAMETER
HR152-2812
TYP MAX
HR152-2815
CONDITION
MIN
MIN TYP MAX
UNITS
OUTPUT
VDC
VOLTAGE
±11.88 ±12.00 ±12.12
±14.85 ±15.00 ±15.15
OUTPUT
CURRENT
OUTPUT
POWER
OUTPUT
RIPPLE
0
—
—
30
±625
15
0
—
—
30
±500
15
mA
W
—
—
0 TO 1 MHz
—
50
—
50
mV p-p
INPUT
CONTINUOUS
18
—
28
—
36
50
18
—
28
—
36
50
VDC
V
VOLTAGE
TRANSIENT 50 ms
INPUT
NO LOAD
—
—
35
—
—
35
mA
CURRENT
INPUT REFL.
RIPPLE
—
25
79
50
—
—
25
79
50
—
mA p-p
%
0 TO 2 MHz
EFFICIENCY
75
75
TRIPLE OUTPUTS
PARAMETER
OUTPUT
HR153-1212
HR153-1215
HR153-2812
HR153-2815
CONDITION
MIN
TYP
MAX
MIN
TYP
MAX
5.05
MIN
TYP
MAX
MIN
4.95
TYP
MAX
UNITS
FULL
LOAD
MAIN
DUAL
4.95
5.00
5.05
4.95
5.00
4.95
5.00
5.05
5.00
5.05
VDC
VOLTAGE
±11.88 ±12.00 ±12.12 ±14.85 ±15.00 ±15.15 ±11.88 ±12.00 ±12.12 ±14.85 ±15.00 ±15.15
1
OUTPUT
MAIN
100
—
—
—
—
—
—
—
—
—
—
—
40
20
2000
±208
10
100
—
—
—
—
—
—
—
—
—
—
—
40
20
2000
±167
10
100
—
—
—
—
—
—
—
—
—
—
—
40
20
2000
±208
10
100
—
—
—
—
—
—
—
—
—
—
—
40
20
2000
±167
10
mA
CURRENT
DUAL
MAIN
OUTPUT
POWER
±DUAL
TOTAL
2.5
15
2.5
15
2.5
15
2.5
15
W
OUTPUT
RIPPLE
MAIN
DUAL
80
80
80
80
mV p-p
0 TO 1 MHz
40
40
40
40
INPUT
CONTINUOUS
10
—
12
—
16
25
10
—
12
—
16
25
18
—
28
—
36
50
18
—
28
—
36
50
VDC
V
VOLTAGE
TRANSIENT 50 ms
INPUT
NO LOAD
—
—
60
—
—
60
—
—
50
—
—
50
mA
CURRENT
INPUT REFL.
RIPPLE
—
50
79
100
—
—
50
79
100
—
—
40
79
80
—
—
40
79
80
—
mA p-p
%
0 TO 2 MHz
EFFICIENCY
76
76
75
75
Note 1. Minimum load required for full output capability on auxiliary outputs. Minimum current can be reduced when dual outputs are used at reduced loads.
B4-45