欢迎访问ic37.com |
会员登录 免费注册
发布采购

HR700 参数 Datasheet PDF下载

HR700图片预览
型号: HR700
PDF下载: 下载PDF文件 查看货源
内容描述: -40 ° C至+ 85°C操作50 V 50 ms的瞬态保护 [–40°C to + 85°C operation 50 V for 50 ms transient protection]
分类和应用:
文件页数/大小: 7 页 / 458 K
品牌: INTERPOINT [ INTERPOINT CORPORATION COMPANY ]
 浏览型号HR700的Datasheet PDF文件第1页浏览型号HR700的Datasheet PDF文件第2页浏览型号HR700的Datasheet PDF文件第4页浏览型号HR700的Datasheet PDF文件第5页浏览型号HR700的Datasheet PDF文件第6页浏览型号HR700的Datasheet PDF文件第7页  
Dc/Dc c
onVerters
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL AND TRIPLE OUTPUT mODELS
parameter
output Voltage
HR700
SERIES
70 WATT
units
VDC
A
HR702-2812
min
typ
2.92
35
30
10
25
1.5
2.0
maX
min
— —
66.5
70
HR702-2815
typ
2.33
35
30
10
25
1.5
2.0
maX
HR703-28512
min
typ
5.05
4.0
1.67
20
20
50
50
2
100
5
300
— 4.90
4.4
5.15
10.0
50
50
60
100
100
25
225
30
600
HR703-28515
typ
4.95
4.0
1.33
20
20
50
50
2
100
5
300
maX
5.10
10.0
3.33
50
50
60
100
100
25
225
30
600
4.90
conDitions
full
loaD
V
in
=
19
to
40
main
main
Dual
main
Dual
maX min
±11.75 ±12 ±12.25
±14.75 ±15 ±15.25
±11.50 ±11.80 ±12.10
±15.05 ±15.30 ±15.75
output
current1,2
output power1,2
5.5
4.2
±
Dual
total
output ripple
full loaD
bw
≤ 2 mHz
66.5
70
100
30
50
W
main
Dual
main
Dual
main
Dual
100 —
— —
30 —
— —
50 —
3.0 —
4.0 —
mV p-p
mV
mV
line regulation
loaD regulation3
V
in
=
19
to
40
no loaD
to full
— —
— —
cross
regulation4
+
p
o
= 20
w to
50
w
-
p
o
= 50
w to
20
w
cross
regulation5
main
+
p
o
= 33
w
Dual
+
p
o
= 3
w to
27
w
-
p
o
= 27
w to
3
w
Dual
+
p
o
= 3
w to
35
w
-
p
o
= 35
w
3.0 —
3.5 —
%
— —
19
80
28
75
25
15
83
15
— —
— —
40
100
35
50
25
19
80
28
75
25
15
83
15
— —
40
100
35
50
25
19
79
2.3
5.4
28
85
30
15
84
6
6.0
9.0
40
115
35
50
10
19
79
2.3
5.0
28
85
30
15
84
6
5.0
7.0
40
115
35
50
10
%
main
+
po
= 3
w to
30
w
Dual
±
p
o
= 15
w
no loaD
inhibiteD
input Voltage
input current
input refl
.
ripple
efficiency
startup Delay
VDC
mA
mA p-p
%
ms
full loaD
bw
10 mHz
Notes
1. n dual output models the maximum combined output power is 70 watts.
O
A maximum of 95% (66.5 W) is available from any single output.
2. n triple output models the maximum combined output power is 60 watts.
O
A maximum of 50 watts is available from a single output.
3. alanced loads
B
4. egulation effect on the negative dual output during the defined
R
conditions.
5. egulation effect on both dual outputs during the defined conditions.
R
www.interpoint.com
Page 3 of 7
HR700 Rev C - 20100212