TEST
PRE-CAP INSPECTION
Method 2017, 2032
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. C, -65°C to 150°C
Method 1010, Cond. B, -55°C to 125°C
CONSTANT ACCELERATION
Method 2001, 3000 g
Method 2001, 500 g
BURN-IN
Method 1015, 160 hours at 125°C
96 hours at 125°C case (typical)
DC/DC C
ONVERTERS
T
ABLE
1: E
NVIRONMENTAL
S
CREENING
STANDARD
/ES
/883 (Class H)*
yes
yes
yes
no
no
no
yes
yes
no
no
no
no
yes
yes
no
no
no
no
yes
yes
no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C
Subgroups 1 and 4: +25°C case
HERMETICITY TESTING
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10
-3
)
FINAL VISUAL INSPECTION
Method 2009
yes
yes
yes
no
no
yes
yes
yes
no
yes
yes
no
no
yes
no
yes
yes
no
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
*883 products are built with element evaluated components and are 100% tested and guaranteed over the full military temperature
range of –55°C to +125°C.
Contact Information:
Interpoint Headquarters USA
Phone: 1-800-822-8782
+425-882-3100
Email:
power@intp.com
www.interpoint.com
Interpoint UK
Phone: +44-1252-815511
Email:
poweruk@intp.com
Interpoint France
Phone: +33-134285455
Email:
powerfr@intp.com
12
21621-001-DTS Rev B This revision supercedes all previous releases.
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. MHF+ Series is a trademark of Interpoint.
Copyright © 1999-2000 Interpoint. All rights reserved.