欢迎访问ic37.com |
会员登录 免费注册
发布采购

MOR2805SY/883 参数 Datasheet PDF下载

MOR2805SY/883图片预览
型号: MOR2805SY/883
PDF下载: 下载PDF文件 查看货源
内容描述: DC / DC转换器, 28伏特的输入 [DC/DC CONVERTERS 28 VOLT INPUT]
分类和应用: 转换器模拟IC信号电路输入元件
文件页数/大小: 16 页 / 465 K
品牌: INTERPOINT [ INTERPOINT CORPORATION COMPANY ]
 浏览型号MOR2805SY/883的Datasheet PDF文件第2页浏览型号MOR2805SY/883的Datasheet PDF文件第3页浏览型号MOR2805SY/883的Datasheet PDF文件第4页浏览型号MOR2805SY/883的Datasheet PDF文件第5页浏览型号MOR2805SY/883的Datasheet PDF文件第7页浏览型号MOR2805SY/883的Datasheet PDF文件第8页浏览型号MOR2805SY/883的Datasheet PDF文件第9页浏览型号MOR2805SY/883的Datasheet PDF文件第10页  
MOR SERIES
120 WATT
AND
S
YNC
The MOR converters
can be synchronized to
the system clock by
applying a TTL compat-
ible sync signal to the
Sync In pin. Sync Out
can be used to synchro-
nize other components
to the MOR converter’s
switching frequency.
DC/DC C
ONVERTERS
O
UT
V
CC
~
5V
~
Sync In
330 pF
1.8 k
Input
Common
10 k
10 k
1k
1 Positive Input
6 Sync In
5 Sync Out
2
Input Common
Positive Output 7
Positive Sense 10
Share 11
Sense Return 9
Output common 8
28V
1 Positive Input
6 Sync In
5 Sync Out
2
Input Common
Positive Output 7
Positive Sense 10
Share 11
Sense Return 9
Output common 8
S
YNC
I
N
+
F
IGURE
7: S
YNC
I
N
The frequency range for external
synchronization is 525 to 625 kHz.
The requirements for an external
signal are 15% to 50% duty cycle,
0
L
0.8 V and 4.5
H
9 V.
Both Sync In and Sync Out are
referenced to input common. Sync
In should be grounded to input
common if not used.
Load
V
CC
~
200
1 Positive Input
6 Sync In
5 Sync Out
2
Input Common
Sync Out
Input
Common
Positive Output 7
Positive Sense 10
Share 11
9
8
Sense Return
Output common
F
IGURE
8: S
YNC
O
UT
F
IGURE
10: P
ARALLELING
P
OSITIVE
S
ENSE
, S
ENSE
R
ETURN
A special remote sensing feature maintains the desired output
voltage at the load. When this feature is not used, connect the
sense lines to their respective output terminals. Remote sensing is
available on single output models only. See Figure 12. Do not
exceed 110% of Vout and maximum output power.
P
OSITIVE
O
UTPUT
, N
EGATIVE
O
UTPUT
AND
O
UTPUT
C
OMMON
Output current is limited to 125% of maximum specified current
under short circuit or load fault conditions.
Single output models operate from no load to full load. Dual output
models with balanced loads operate from no load to full load. For
dual models with unbalanced loads, at least 10% of the total output
power must be drawn
from the positive output
Positive Output 7
at all times, however, the
1 Positive Input
Inhibit 2
negative output does not
+
MOR
require a minimum load.
Output Common 8
Load
Dual Output
See note 7, cross regula-
tion, under the Electrical
2 Input Common
Negative Output 9
Characteristics Tables.
Dual outputs may be
F
IGURE
11: “S
TACKED
” O
UTPUT
“stacked” to double the
output voltage.
S
HARE
(P
ARALLELING
)
By using the Share pin, up to five single or dual converters may be
paralleled for a total output power of over 500 watts (90% Pout /
converter, max.). The converters will share within 10% of each
other at 25 to 90% rated power. MOR converters feature true n+1
redundancy for reliability in critical applications. See Figure 9 for
the proper connections.
Share
260 k
10 k
Sense
Return
T
YPICAL
C
ONNECTIONS
1
6
28V
Positive Input
Sync In
Inhbit 1
F
IGURE
9: S
HARE
All Positive Outputs and Positive Senses should be connected to
a common point. All Negative Outputs and Sense Returns should
be connected to a common point. The Share pin is referenced to
Sense Return. Leave the share pin floating (unconnected) if not
used.
28V
4
2
MOR
Single
Output
Positive Output 7
Positive Sense 10
Inhibit 2 12
Sense Return 9
Output Common 8
Load
+
Input Common
1
6
4
2
Positive Input
Sync In
Inhbit 1
MOR
Dual
Output
Positive Output 7
Inhibit 2 12
Output Common 8
+
Load
0
Load
Input Common
Negative Output 9
F
IGURE
12: C
ONNECTIONS
6