Crane Aerospace & Electronics Power Solutions
sMrt28 single, Dual and triple space Dc/Dc converters
28 VOLt Input – 35 Watt – space quaLIFIeD
Electrical Characteristics: -55°C to +125°C T
C
, 28 VDC Vin, 100% load, unless otherwise specified.
DUAL OUTPUT MODELS
parameter
Output VOltage
Output Current
2, 3
Output pOwer
2, 3
V
In
= 19
tO
56 VDC
Output rIpple
lIne regulatIOn
2
lOaD regulatIOn
tOtal regulatIOn
1
V
OUT
Input VOltage
4
Input Current
Input rIpple
Current
4
eFFICIenCy
lOaD Fault
5, 6
Step lOaD
reSpOnSe
6, 7, 8
Step lIne
reSpOnSe
1, 6, 7
Start-up
9
pOwer DISSIpatIOn
reCOVery
1
tranSIent
reCOVery
19 - 50 - 19 V
In
tranSIent
reCOVery
Delay
nO lOaD anD Full
OVerShOOt
CapaCItIVe lOaD
1
t
C
= 25°C
unCOnDItIOnally
Stable, Start-up
Delay InCreaSeD
COnDItIOnS
V
Out
a
V
Out
b
V
Out
a
V
Out
b
V
Out
a
V
Out
b
10
k
h
z
- 20 mh
z
V
In
= 19, 50 VDC
V
In
= 19, 50 VDC
all COnDItIOnS OF
lIne, lOaD, agIng,
temp anD raDIatIOn
COntInuOuS
tranSIent 100
ms
InhIbIteD
4
nO lOaD
10
kHz
- 20
MHz
SMRT2805D
MIn
4.90
4.90
—
—
0
0
—
—
—
—
±4.6
19
0
—
—
—
66
—
—
—
—
—
—
—
—
—
TYP
5.00
5.00
—
—
—
—
—
—
5
—
—
28
—
—
—
10
—
—
—
—
—
—
—
—
—
—
MAX
5.10
5.10
3.0
3.0
15
15
200
30
40
70
±5.4
56
80
50
110
50
—
28
25
±450
3
±500
4
25
50
5000
SMRT2812D
MIn
11.76
11.76
—
—
0
0
—
—
—
—
±10.9
19
0
—
—
—
75
—
—
—
—
—
—
—
—
—
TYP
12.00
12.00
—
—
—
—
—
5
5
—
—
28
—
—
—
10
—
—
—
—
—
—
—
—
—
—
MAX
12.24
12.24
1.46
1.46
17.5
17.5
200
25
50
100
±13.1
56
80
50
110
150
—
20
25
±450
2
±1000
3
20
350
5000
SMRT2815D
MIn
14.70
14.70
—
—
0
0
—
—
—
—
±14.0
19
0
—
—
—
75
—
—
—
—
—
—
—
—
—
TYP
15.00
15.00
—
—
—
—
—
5
5
—
—
28
—
—
—
10
—
—
—
—
—
—
—
—
—
—
MAX
15.30
15.30
1.17
1.17
17.5
17.5
180
30
40
70
±16.0
56
80
50
110
50
—
20
25
±575
3
±700
4
25
150
5000
unItS
VDC
A
W
mV p-p
mV
mV
VDC
VDC
V
mA
mA p-p
%
W
ms
mV pk
ms
mv pk
ms
ms
mV pk
µF
notes
1. guaranteed by design, not tested.
2. The specified maximum current/power is available from each output.
3. To maintain tight regulation over the full input voltage range a minimum load of 2% of full load should be used on all outputs.
4. Converters meet MIL-STD-461 specification revisions for conducted emissions C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much less, the
limit in the characteristic table is based on measurement resolution..
5. Maximum power dissipation when output is shorted.
6. Recovery time is measured from application of the transient to point at which V
OUT
is within 1% of V
OUT
at final value.
7. Transition time >10 µs.
8. Half load to/from full load.
9. Measured from release of inhibit or input voltage step
www.interpoint.com
Page 9 of 19
SMRT28 Rev E - 20100216