DC/DC C
ONVERTERS
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
1
OUTPUT POWER
1
OUTPUT RIPPLE VOLT.
LINE REGULATION
CONDITIONS
+V
OUT
–V
OUT
V
IN
= 16 to 40 VDC
Tc = –55°C to +125°C
V
IN
= 16 to 40 VDC
Tc = –55°C to +125°C
10 kHz - 2 MHz
Vin = 16 to 40 VDC
Tc = –55°C to +125°C
+V
OUT
–V
OUT
LOAD REGULATION
NO LOAD TO FULL
Tc = –55°C to +125°C
+V
OUT
–V
OUT
CROSS REGULATION
2
INPUT VOLTAGE
+P
O
= 30 - 70 %, –P
O
=70 - 30%
–P
O
= 30 - 70 %, +P
O
= 70 - 30%
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
5
50 msec
NO LOAD
FULL LOAD
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
3, 4
INHIBITED
10 kHz TO 10 MHz
Tc = –55°C to +125°C
POWER DISSIPATION
SHORT CIRCUIT
RECOVERY
50% - 100% - 50% BALANCED
TRANSIENT
RECOVERY
4, 5
STEP LINE RESP.
4, 5
TRANSIENT
RECOVERY
START-UP
16 TO 40 VDC
40 TO 16 VDC
—
—
—
10
100
5
120
400
8
—
—
—
10
100
3.7
120
400
6
—
—
—
—
—
20
40
100
200
—
—
20
40
100
200
—
—
MIN
4.95
4.9
—
—
—
SMSA 2805D
TYP
5.00
5.0
±500
—
—
MAX
5.05
5.1
800
5
300
SMSA2812D
MIN
11.88
11.76
—
—
—
TYP
12.00
12.00
±208
—
80
MAX
12.12
12.24
333
5
300
SMSA SERIES
5 WATT
SMSA2815D
MIN
14.85
14.70
—
—
—
TYP
15.00
15.00
±167
—
120
MAX
15.15
15.30
267
5
300
mA
W
mV p-p
UNITS
VDC
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, radiation level O, unless otherwise specified.
10
40
50
180
mV
10
50
3
50
200
6
mV
%
16
—
—
—
—
—
—
65
—
—
—
—
—
—
—
—
—
—
28
—
30
248
3
50
60
70
1.3
—
±200
200
±200
±200
300
800
10
0
40
50
50
—
5
200
300
—
2.1
50
±550
500
±500
±500
750
2000
30
500
16
—
—
—
—
—
—
67
—
—
—
—
—
—
—
—
—
—
28
—
40
235
3
50
60
73
1.3
1
±200
200
±200
±200
300
800
10
0
40
50
63
—
5
200
300
—
1.7
30
±550
500
±500
±500
750
2000
30
500
16
—
—
—
—
—
—
68
—
—
—
—
—
—
—
—
—
—
28
—
38
235
3
50
60
73
1.3
1
±220
200
±600
±600
500
500
10
0
40
50
60
—
5
200
300
—
1.6
50
±600
500
±1500
±1500
1200
1200
25
500
VDC
V
mA
INPUT CURRENT
mA p-p
%
W
ms
mV
µs
mV pk
µs
ms
mV pk
STEP LOAD
RESPONSE
16 TO 40 VDC
40 TO 16 VDC
DELAY
OVERSHOOT
5
Notes
1. Up to 4 watts (80% of full power) is available from either output providing the
opposite output is carrying 20% of total power.
2. Shows regulation effect on the minus output during the defined cross loading
conditions, with 80% and 20% referring to the total output power of the
converter. See Figures 15 and 16.
3. Indefinite short circuit protection not guaranteed above 125°C (case).
4. Recovery time is measured from application of the transient to point at which
V
OUT
is within 1% of V
OUT
at final value.
5. Guaranteed but not tested.
®
47