AC100 SERIES
Rev C December 2007
5. Main Features and Functions
5.1 Operating Temperature Range
Intronics power’s AC100 series converters highly efficient converter
design has resulted in its ability to operate ambient temperature
environment (0℃ to 40℃). Due consideration must be given to the de-
rating curves when ascertaining maximum power that can be drawn
from the converter. The maximum power drawn is influenced by a
number of factors, such as:
Input voltage range.
Output load current.
These can be effective heat sinks for the converter.
5.4 Over Voltage Protection
All different voltage models have a full continuous over voltage
protection. The power module will supply up to 150% of rated voltage.
In the event of an over voltage converter will go into a hiccup mode
protection.
5.5 V-Sense
V-sense measures the use as outputting the voltage.
The maximum length of the sense lines is 1200mm.
The min gauge wire that can be used 26AWG.
If does not use and needn't need to join .
5.2 Output Voltage Adjustment
The output voltage on all models is in the range from +5% to –5%
but can't exceed the watt value of the products .
6. Safety
CB Approval
TUV Approval
UL Approval
5.3 Over Current Protection
All different voltage models have a full continuous short-circuit
protection. The unit will auto recover once the short circuit is removed.
To provide protection in a fault condition, the unit is equipped with
internal over-current protection. The unit operates normally once the
fault condition is removed. The power module will supply up to 150% of
rated current. In the event of an over current converter will go into a
hiccup mode protection.
7. Applications
Page
6