IR2117(S)/IR2118(S) & (PbF)
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V, C
L
= 1000 pF and T
A
= 25°C unless otherwise specified. The dynamic electrical characteristics
are measured using the test circuit shown in Figure 3.
Symbol
t
on
t
off
t
r
t
f
Definition
Turn-on propagation delay
Turn-off propagation delay
Turn-on rise time
Turn-off fall time
Min. Typ. Max. Units Test Conditions
—
—
—
—
125
105
80
40
200
180
130
65
ns
V
S
= 0V
V
S
= 600V
Static Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V and T
A
= 25°C unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters are referenced to
COM. The V
O
and I
O
parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
Symbol
V
IH
V
IL
V
OH
V
OL
I
LK
I
QBS
I
QCC
I
IN+
I
IN-
V
BSUV+
V
BSUV-
V
CCUV+
V
CCUV-
I
O+
Definition
input voltage - logic “1” (IR2117) logic “0” (IR2118)
Input voltage - logic “0” (IR2117) logic “1” (IR2118)
High level output voltage, V
BIAS
- V
O
Low level output voltage, V
O
Offset supply leakage current
Quiescent V
BS
supply current
Quiescent V
CC
Supply Current
Logic “1” input bias current
Logic “0” input bias current
(IR2117)
(IR2118)
(IR2117)
(IR2118)
V
BS
supply undervoltage positive going threshold
V
BS
supply undervoltage negative going threshold
V
CC
supply undervoltage positive going threshold
V
CC
supply undervoltage negative going threshold
Output high short circuit pulsed current
Min. Typ. Max. Units Test Conditions
9.5
—
—
—
—
—
—
—
—
7.6
7.2
7.6
7.2
200
—
—
—
—
—
50
70
20
—
8.6
8.2
8.6
8.2
250
—
6.0
100
100
50
240
340
40
1.0
9.6
9.2
9.6
9.2
—
V
O
= 0V
V
IN
= Logic “1”
PW
≤
10
µs
V
O
= 15V
V
IN
= Logic “0”
PW
≤
10
µs
V
µA
V
mV
I
O
= 0A
I
O
= 0A
V
B
= V
S
= 600V
V
IN
= 0V or V
CC
V
IN
= 0V or V
CC
V
IN
= V
CC
V
IN
= 0V
V
IN
= 0V
V
IN
= V
CC
I
O-
Output low short circuit pulsed current
420
500
—
mA
www.irf.com
3