IR2130/IR2132(J)(S) & (PbF)
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS1,2,3
) = 15V, V
S0,1,2,3
= V
SS
, C
L
= 1000 pF and T
A
= 25°C unless otherwise specified. The dynamic
electrical characteristics are defined in Figures 3 through 5.
Symbol
t
on
t
off
t
r
t
f
t
itrip
t
bl
t
flt
t
flt,in
t
fltclr
DT
SR+
SR-
Definition
Turn-On Propagation Delay
Turn-Off Propagation Delay
Turn-On Rise Time
Turn-Off Fall Time
ITRIP to Output Shutdown Prop. Delay
ITRIP Blanking Time
ITRIP to
FAULT
Indication Delay
Input Filter Time (All Six Inputs)
LIN1,2,3
to
FAULT
Clear Time
Deadtime
(IR2130)
(IR2132)
Operational Amplifier Slew Rate (+)
Operational Amplifier Slew Rate (-)
Figure Min. Typ. Max. Units Test Conditions
11
12
13
14
15
—
16
—
17
18
18
19
20
500
300
—
—
400
—
335
—
6.0
1.3
0.4
4.4
2.4
675
425
80
35
660
400
590
310
9.0
2.5
0.8
6.2
3.2
850
550
125
55
920
—
845
—
12.0
3.7
1.2
—
—
V
IN
= 0 & 5V
V
S1,2,3
= 0 to 600V
V
IN
, V
ITRIP
= 0 & 5V
V
ITRIP
= 1V
V
IN
, V
ITRIP
= 0 & 5V
V
IN
= 0 & 5V
V
IN
, V
ITRIP
= 0 & 5V
V
IN
= 0 & 5V
ns
µs
V/µs
NOTE: For high side PWM, HIN pulse width must be
≥ 1.5µsec
Static Electrical Characteristics
V
BIAS
(V
CC
, V
BS1,2,3
) = 15V, V
S0,1,2,3
= V
SS
and T
A
= 25°C unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters
are referenced to V
SS
and are applicable to all six logic input leads:
HIN1,2,3
&
LIN1,2,3
. The V
O
and I
O
parameters
are referenced to V
S0,1,2,3
and are applicable to the respective output leads: HO1,2,3 or LO1,2,3.
Symbol
V
IH
V
IL
V
IT,TH+
V
OH
V
OL
I
LK
I
QBS
I
QCC
I
IN+
I
IN-
I
ITRIP+
I
ITRIP-
V
BSUV+
V
BSUV-
V
CCUV+
V
CCUV-
R
on,FLT
Definition
Logic “0” Input Voltage (OUT = LO)
Logic “1” Input Voltage (OUT = HI)
ITRIP Input Positive Going Threshold
High Level Output Voltage, V
BIAS
- V
O
Low Level Output Voltage, V
O
Offset Supply Leakage Current
Quiescent V
BS
Supply Current
Quiescent V
CC
Supply Current
Logic “1” Input Bias Current (OUT = HI)
Logic “0” Input Bias Current (OUT = LO)
“High” ITRIP Bias Current
“Low” ITRIP Bias Current
V
BS
Supply Undervoltage Positive Going
Threshold
V
BS
Supply Undervoltage Negative Going
Threshold
V
CC
Supply Undervoltage Positive Going
Threshold
V
CC
Supply Undervoltage Negative Going
Threshold
FAULT
Low On-Resistance
Figure Min. Typ. Max. Units Test Conditions
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
2.2
—
400
—
—
—
—
—
—
—
—
—
7.5
7.1
8.3
8.0
—
—
—
490
—
—
—
15
3.0
450
225
75
—
8.35
7.95
9.0
8.7
55
—
0.8
580
100
100
50
30
4.0
650
400
150
100
9.2
8.8
9.7
9.4
75
Ω
V
V
mV
µA
mA
µA
nA
V
IN
= 0V, I
O
= 0A
V
IN
= 5V, I
O
= 0A
V
B
= V
S
= 600V
V
IN
= 0V or 5V
V
IN
= 0V or 5V
V
IN
= 0V
V
IN
= 5V
ITRIP = 5V
ITRIP = 0V
www.irf.com