IRFPG50PbF
TO-247AC Package Outline
Dimensions are shown in millimeters (inches)
-D-
15.90 (.626)
15.30 (.602)
-B-
3.65 (.143)
3.55 (.140)
-A-
0.25 (.010) M D B M
5.50 (.217)
5.30 (.209)
4.70 (.185)
2.50 (.089)
1.50 (.059)
4
NOTES:
1 DIMENSIONING & TOLERANCING
PER ANSI Y14.5M, 1982.
2 CONTROLLING DIMENSION : INCH.
3 CONFORMS TO JEDEC OUTLINE
TO-247-AC.
20.30 (.800)
19.70 (.775)
1
2
3
2X
5.50 (.217)
4.50 (.177)
-C-
14.80 (.583)
14.20 (.559)
4.30 (.170)
3.70 (.145)
2.40 (.094)
2.00 (.079)
2X
5.45 (.215)
2X
1.40 (.056)
3X 1.00 (.039)
0.25 (.010) M
3.40 (.133)
3.00 (.118)
C A S
0.80 (.031)
3X 0.40 (.016)
2.60 (.102)
2.20 (.087)
LEAD ASSIGNMENTS
1-
2-
3-
4-
GATE
DRAIN
SOURCE
DRAIN
TO-247AC Part Marking Information
EXAMPLE: THIS IS AN IRFPE30
WITH ASSEMBLY
LOT CODE 5657
ASSEMBLED ON WW 35, 2000
IN THE ASSEMBLY LINE "H"
Note:
"P" in assembly line
position indicates "Lead-Free"
INTERNATIONAL
RECTIFIER
LOGO
ASSEMBLY
LOT CODE
PART NUMBER
IRFPE30
56
035H
57
DATE CODE
YEAR 0 = 2000
WEEK 35
LINE H
Data and specifications subject to change without notice.
IR WORLD HEADQUARTERS:
233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.10/03
8