IS42S83200C
IS42S16160C
AC CHARACTERISTICS
(AC operating conditions unless otherwise noted)
Parameter
Symbol
-6
Min
6
10
5.4
6
2.5
2.5
2.5
2.5
1.5
1.0
0.3
1.5
5.4
-7
Max
Min
7
10
5.4
6
2.5
2.5
2.5
2.5
1.5
1.0
0.3
1.5
5.4
6
-75
Max
Min
75
Max
Unit
Note
CAS latency=3
CLK cycle time
CAS latency=2
CAS latency=3
CLK to valid output delay
CAS latency=2
CAS latency=3
Output data hold time
CAS latency=2
CLK high pulse width
CLK low pulse width
Input setup time
Input hold time
Transition time of CLK
CAS latency=3
CLK to output in Hi-Z
CAS latency=2
t
CC (3)
t
CC (2)
t
SAC (3)
t
SAC (2)
t
OH (3)
t
OH (2)
t
CH
t
CL
t
SI
t
HI
t
T
ns
10
5.4
ns
6
2.5
ns
2.5
2.5
2.5
1.5
1.0
0.3
1.5
5.4
ns
6
6
1
1,2
2
ns
n
s
ns
ns
ns
3
3
3
3
t
SHZ
NOTES :
1. Parameters depend on programmed CAS latency.
2. If clock rising time is longer than 1ns, (tr/2-0.5)ns should be added to the parameter.
3. Assumed input rise and fall time (tr & tf) = 1ns.
If tr & tf is longer than 1ns, transient time compensation should be considered,
i.e., [(tr + tf)/2-1]ns should be added to the parameter.
Integrated Silicon Solution, Inc. — www.issi.com
Rev.
C
04/02/09
9