SAW Bandpass Filter F2G23
Specifications
Fc = 2250 MHz
Terminating source impedance
Terminating load impedance
: 50Ω
: 50Ω
Minimum
Center Frequency ( Fc )
Insertion Loss (In Fc +/-50 MHz)
Insertion Loss (In 2230 ~ 2240 MHz)
Amplitude Ripple (In Fc +/- 50 MHz)
VSWR (In Fc +/- 50 MHz)
-
-
-
-
-
Typical
2250
3.2
2.2
1.9
1.9
Maximum
-
4.5
3.0
3.0
2.5
Unit
MHz
dB
dB
dBp-p
-
Relative Attenuation
D.C ~ 2160 MHz
2340 ~ 4000 MHz
25
25
28
28
-
-
dB
Input/Output Impedance
50
Ohms
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances
I T F Co., Ltd.
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
Part No.
Rev. Date
Rev.
NCNC02-F2G23
2012-3-29
AS 01
2/7