Technical data - mechanical design
F 304
Number of digits
Measuring range
Housing type
Mounting
Dimensions W x H x L
Cutout dimensions
Installation depth
F 314
Number of digits
Measuring range
Housing type
Mounting
Dimensions W x H x L
Cutout dimensions
Installation depth
F 324
Number of digits
Measuring range
Housing type
Mounting
Dimensions W x H x L
Cutout dimensions
Installation depth
F 364
Number of digits
Measuring range
Housing type
Mounting
Dimensions W x H x L
Cutout dimensions
Installation depth
6-digits with reset button
999 999
Built-in housing
Front panel with 4 screws
66.5 x 37 x 75 mm
51 x 26 mm
72 mm
6-digits with reset button
8-digits without reset button
999 999 and 99 999 999
Built-in housing
Front panel with spring clips
53.2 x 28.2 x 61 mm
51 x 26 mm
77.5 mm
6-digits with reset button
8-digits without reset button
999 999 and 99 999 999
Built-in housing
Front panel with 2 screws
60 x 50 x 61 mm
51 x 26 mm
77.5 mm
6-digits with reset button
8-digits without reset button
999 999 and 99 999 999
Socket box
Socket box
50 x 25 x 85.8 mm
50 x 25 mm
85.9 mm
Trigger level
Max. counting speed 10 pulses/s
Voltage
Power
Min. pulse duration
Min. pulse interval
Switch on time (at 25 °C)
Voltage
Power
Min. pulse duration
Min. pulse interval
Switch on time (at 25 °C)
Accessories
Front panels for F 304
Z 100.01A
Front panel with transparent protective cover,
for socket box 50 x 25 mm
Front frame with cylinder lock provided on
transparent cover
Front frame, insertion cutout 50 x 25 mm
24/110 VAC ±10 %
230 VAC +6/-10 %
2.4 VA
50 ms
50 ms
100 %
24 VDC ±10 %
2.2 W
25 ms
25 ms
100 %
Connection diagram
4
3
-(+)
Voltage
+(-)
Encoder
Max. counting speed 20 pulses/s
Front frames for F 304
Subject to modification in technic and design. Errors and omissions excepted.
2/12/2008
Z 105.02A
Z 107.01A